节点文献
Neutron collimator design of neutron radiography based on the BNCT facility
【摘要】 For the research of CCD neutron radiography,a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy(BNCT)reactor.Based on the Geant4 simulations,the preliminary choice of the size of the collimator was determined.The materials were selected according to the literature data.Then,a collimator was constructed and tested on site.The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0×106n/cm2/s,the maximum collimation ratio(L/D)is 58,the Cd-ratio(Mn)is 160 and the diameter of collimator end is 10 cm.This neutron collimator is considered to be applicable for neutron radiography.
【Abstract】 For the research of CCD neutron radiography, a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy(BNCT) reactor. Based on the Geant4 simulations, the preliminary choice of the size of the collimator was determined. The materials were selected according to the literature data. Then, a collimator was constructed and tested on site. The results of experiment and simulation show that the thermal neutron flux at the end of the neutron collimator is greater than 1.0×106n/cm2/s, the maximum collimation ratio(L/D) is 58, the Cd-ratio(Mn) is 160 and the diameter of collimator end is 10 cm. This neutron collimator is considered to be applicable for neutron radiography.
【Key words】 neutron radiography; ICCD camera; thermal neutron collimator; thermal neuron flux; collimation ratio(L/D;
- 【文献出处】 Chinese Physics C ,中国物理C , 编辑部邮箱 ,2014年02期
- 【分类号】O571.56
- 【下载频次】86