节点文献
液闪TDCR活度测量装置的研制
Construction and Implementation of a Liquid Scintillation TDCR System
【摘要】 建立了基于效率计算的液闪三双符合比活度测量装置,通过设定甄别阈、扩展死时间、符合技术手段消除了光电倍增管的热噪声和余后脉冲的影响。该装置测量氚水、14C和99Tc的双管符合探测效率达到54%、96.2%和97.2%。用NIST氚水标准物质对新建立的实验装置进行验证,En数检验结果满意。
【Abstract】 The liquid scintillation triple-to-double coincidence ratio(TDCR) system recently constructed is presented.In order to eliminate the influence of after pluses and thermal noises,the technology of discrimination threshold setting,coincidence counting and extendible dead time is in application.The highest efficiency of tritium water,14C and 99Tc is about 54%,96.2% and 97.2%separately.The NIST SRM of tritium water is measured to verify the performance of the counter,and the result agreed well with certified activitiy value with En criterion.
【关键词】 计量学;
液闪计数器;
三双符合比方法;
活度测量;
【Key words】 Metrology; Liquid scintillation counter; TDCR method; Activity measurement;
【Key words】 Metrology; Liquid scintillation counter; TDCR method; Activity measurement;
- 【文献出处】 计量学报 ,Acta Metrologica Sinica , 编辑部邮箱 ,2014年01期
- 【分类号】TH724