节点文献
四碘荧光素钠-邻啡啰啉荧光光谱法测定水中镉
Determination of Cadmium in the Water by Fluorometry with Tetraiodofluorescein Sodium Salt and 1,10-phenantroline
【摘要】 目的建立一种荧光光谱测定水中镉的新方法。方法在pH=6.0的乙酸-乙酸钠(HAc-NaAc)缓冲介质中,镉(Cd2+)与四碘荧光素钠、邻啡啰啉反应形成络合物,体系的最大激发波长为525nm,发射波长为531 nm,在一定范围内,其荧光强度与Cd2+的浓度成线性关系。结果 Cd2+浓度在3.92×10-6mol/L~2.00×10-5mol/L范围内,荧光强度变化值(ΔF)与镉离子浓度(cCd2+)有良好的线性关系,线性方程为ΔF=58.9c(×10-5mol/L)+4.8,相关系数r=0.999 2,检出限为1.91×10-6mol/L,样品加标回收率为86.6%~101.5%。结论本方法可直接用于水中镉的测定,选择性好,准确可靠,结果满意。
【Abstract】 Objective To establish a new method of fluorescence spectroscopy to determine trace cadmium in water.Methods At pH = 6. 0 HAc-NaAc buffer medium,the complex with Cd2 +,Tetraiodofluorescein sodium salt and 1,10-Phenanthroline hydrate was formed. The results showed that with maximum wavelength for 525 nm and the emission wavelength for 531 nm there was a good linear relationship between the fluorescence intensity and the concentration of Cd2 +. Results Among the range of 3. 92 × 10- 6mol /L ~ 2. 00 × 10- 5mol /L,the linear equation was ΔF = 58. 9c( × 10- 5mol /L) + 4. 8,and the correlation coefficient was 0. 9992. The average recoveries were between 86. 6% and 101. 5%. The method detection limit was 1. 91 × 10- 6mol /L. Conclusion The proposed method is sensitive,selective and simple,and has been used successfully in the determination of cadmium in water samples,which has a good satisfactory results.
【Key words】 cadmium; fluorescence spectrometry; tetraiodofluorescein sodium salt; 1,10-phenantroline;
- 【文献出处】 中南医学科学杂志 ,Medical Science Journal of Central South China , 编辑部邮箱 ,2014年06期
- 【分类号】R123.1
- 【下载频次】77