Effect of temperature on noninvasive blood glucose monitoring in vivo using optical coherence tomography

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 苏亚孟卓王龙志于海民刘铁根

【Author】 Ya Su;Zhuo Meng;Longzhi Wang;Haimin Yu;Tiegen Liu;Polarization Research Center, College of Precision Instrument & Opto-electronics Engineering and Key Laboratory of Opto-electronics Information and Technical Science,Ministry of Education, Tianjin University;Suzhou Opto-ring Co. Ltd.;College of Automobile and Transportation, Tianjin University of Technology and Education;

【机构】 Polarization Research Center, College of Precision Instrument & Opto-electronics Engineering and Key Laboratory of Opto-electronics Information and Technical Science,Ministry of Education, Tianjin UniversitySuzhou Opto-ring Co. Ltd.College of Automobile and Transportation, Tianjin University of Technology and Education

【摘要】 Noninvasive glucose monitoring(NIGM) techniques based on optical coherence tomography(OCT) are affected by several perturbing factors, including variation of tissue temperature. We first design a temperature control module integrated with an optical scanning probe to precisely control the temperature of skin tissues. We investigate the influence of temperature on NIGM with OCT by correlation analysis at different depths of in vivo human skin. On average, the relative changes in attenuation coefficient( μt) per 1 °C of temperature lead to 0.30 ± 0.097 mmol/L prediction error of blood glucose concentration. For NIGM measurement methods using optical properties of the tissues, this effect can be taken into account.

【Abstract】 Noninvasive glucose monitoring(NIGM) techniques based on optical coherence tomography(OCT) are affected by several perturbing factors, including variation of tissue temperature. We first design a temperature control module integrated with an optical scanning probe to precisely control the temperature of skin tissues. We investigate the influence of temperature on NIGM with OCT by correlation analysis at different depths of in vivo human skin. On average, the relative changes in attenuation coefficient( μt) per 1 °C of temperature lead to 0.30 ± 0.097 mmol/L prediction error of blood glucose concentration. For NIGM measurement methods using optical properties of the tissues, this effect can be taken into account.

【基金】 supported by the National“973”Program of China(No.2010CB327806);the International Science&Technology Cooperation Program of China(No.2010DFB13180);the Medical Instruments and New Medicine Program of Suzhou(No.ZXY2012026);the Foundation Research Project of Jiangsu Province(No.BK20130374)
  • 【文献出处】 Chinese Optics Letters ,中国光学快报(英文版) , 编辑部邮箱 ,2014年11期
  • 【分类号】R197.39
  • 【被引频次】5
  • 【下载频次】44