【摘要】 目的研究稀释血清及EXCEL与MVS在线性性能验证中的应用价值。方法分别以收集到的低值混合血清和用去离子水2~3倍稀释后的低值混合血清与同一高浓度血清配制成系列浓度标本进行线性实验,实验结果分别用EXCEL和MVS两个软件统计判定线性。结果 3个稀释血清的实验,两个软件均判定为线性;在6个实验中,肌酐(CREA)原血清实验结果 EXCEL判定为线性,MVS判定为非线性,但在决定性浓度水平,两个回归方程的结果差异分别为-2.02μmol/L和4.23μmol/L,均小于两种浓度水平下CLIA′88最大允许误差(26.52μmol/L和39.78μmol/L)的1/9,其余5个实验两种统计软件均判定为线性。结论对低值血清用去离子水适当稀释不影响线性性能验证;在线性性能验证中,EXCEL可以满足验证需要,MVS对线性的判定更为严格。

【Abstract】 Objective To study the application value of diluted serum and EXCEL and MVS in the linear performance verification.Methods The series of concentration samples were prepared by mixing the collected low value mixed serum and the low value mixed serum diluted with 2-3times of deionized water and the same high concentration serum for conducting the linear experiments.The linearity of the experimental results was statistically judged by the two softwares of EXCEL and MVS.Results The 3diluted serum experiments were linear by the judgement of the two softwares;in 6experiments,the original serum experimental results of CREA were linear by the judgement of EXCEL and nonlinear by the judgement of MVS,but the decisive concentration levels,the differences of the two regression equations were-2.02μmol/L and 4.23μmol/L respectively,which were less than 1/9of CLIA′88maximum allowable error under the two concentrations(26.52μmol/L and 39.78μmol/L),the remaining 5experiments were linear by the judgement of the two softwares.Conclusion The low value serum appropriately diluted by deionized water does not affect the linear performance verification;in the linear performance verification,EXCEL can meet the verification needs and MVS is more strict in judging linearity.

  • 【文献出处】 国际检验医学杂志 ,International Journal of Laboratory Medicine , 编辑部邮箱 ,2014年16期
  • 【分类号】R446.11
  • 【下载频次】42
节点文献中: 

本文链接的文献网络图示:

本文的引文网络