节点文献

基于试验方差分析的血氧测量波长选取的研究

Wavelength Selection of the Oximetry Based on Test Analysis of Variance

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 林凌李威曾锐利刘瑞安李刚吴晓荣

【Author】 LIN Ling;LI Wei;ZENG Rui-li;LIU Rui-an;LI Gang;WU Xiao-rong;State Key Laboratory of Precision Measurement Technology and Instruments,Tianjin University;Department of Automobile Engineering,Military Transportation University;College of Physics & Electronic Information,Tianjin Normal University;Tianjin Key Laboratory of Biomedical Detecting Techniques &Instruments,Tianjin University;

【机构】 天津大学精密测试技术及仪器国家重点实验室军事交通学院军用车辆系天津师范大学物理与电子信息学院天津大学天津市生物医学检测技术与仪器重点实验室

【摘要】 为了提高血氧饱和度光谱测量的精度和可靠性,增强血氧饱和度测量数据的有效性,提出了基于试验方差分析的血氧测量波长选取的方法。通过分析不同波长组合对应的血氧饱和度系数分布情况,合理地利用统计理论,从中选取较好的波长组合。实验中以不同血氧饱和度临床数据为基础,建立了不同波长组合(660和940nm,660和805nm,805和940nm)计算出的血氧饱和度系数的单因素试验方差分析模型,参照分析模型中的F指标和p参数,比较分析不同波长组合的显著性,进而从光谱数据中选取出相对较好的波长组合,为进一步建模分析提供了可靠的中间数据。结果表明,选取660和805nm的波长组合引入的总误差相对较小,能更显著的代表血氧饱和度的变化,相比其他的波长组合进行分析能够提高血氧测量精度。本研究将试验方差分析方法用于血氧测量中波长组合的优选,效果显著,为血氧饱和度的测量和其他相关光谱的特征波长选取以及定量分析提供了新思路。试验方差分析方法有助于从光谱中提取代表被测量的有效信息。

【Abstract】 In order to improve the precision and reliability of the spectral measurement of blood oxygen saturation,and enhance the validity of the measurement,the method of test analysis of variance was employed.Preferred wavelength combination was selected by the analysis of the distribution of the coefficient of oximetry at different wavelength combinations and rational use of statistical theory.Calculated by different combinations of wavelengths(660 and 940nm,660 and 805nm and 805 and 940nm)through the clinical data under different oxygen saturation,the single factor test analysis of variance model of the oxygen saturation coefficient was established,the relative preferabe wavelength combination can be selected by comparative analysis of different combinations of wavelengths from the photoelectric volume pulse to provide a reliable intermediate data for further modeling.The experiment results showed that the wavelength combination of 660 and 805nm responded more significantly to the changes in blood oxygen saturation and the introduced noise and method error were relatively smaller of this combination than other wavelength combination,which could improve the measurement accuracy of oximetry.The study applied the test variance analysis to the selection of wavelength combination in the blood oxygen result measurement,and the result was significant.The study provided a new idea for the blood oxygen measurements and other related spectroscopy quantitative analysis.The method of test analysis of variance can help extract the valid information which represents the measured values from the spectrum.

【基金】 国家自然科学基金项目(30973964);天津市应用基础及前沿技术研究计划(11JCZDJC17100);天津市科技计划项目:科技型中小企业创新基金项目(10ZXCXSY10400)资助
  • 【文献出处】 光谱学与光谱分析 ,Spectroscopy and Spectral Analysis , 编辑部邮箱 ,2014年07期
  • 【分类号】O657.33;R318.6
  • 【被引频次】11
  • 【下载频次】481
节点文献中: 

本文链接的文献网络图示:

本文的引文网络