节点文献

臭氧发生设备监测与故障诊断的研究

Monitoring and Fault Diagnosis of Ozone Generator

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 宋超刘钟阳周博

【Author】 SONG Chao;LIU Zhong-yang;ZHOU Bo;School of Electrical Engineering,Dalian University of Science and Technology;

【机构】 大连理工大学电气工程学院

【摘要】 臭氧发生器利用高频高压电源和介质阻挡放电产生臭氧,可能出现故障点较多,较难分辨,故障特征的提取和监测点的设置成为臭氧发生器故障诊断的关键。运用电流监测表征电功率变化值,配合温度变化的监测,根据监测点的监测值变化情况判断设备的运行状态,研究了臭氧发生设备的无人在线监测与故障诊断系统。结构简单可行,满足无人状态下监测的实时性和准确性。

【Abstract】 In am ozone generator,high-frequency high-voltage power supply and dielectric barrier discharge are used to generate ozone so that there may be more points of fault which are difficult to distinguish. The acquisition of fault feature and setup of monitoring points becomes the key to the fault diagnosis of the ozone generator. The operational status of the equipment is judged according to the variations of monitored values with respect to the electric power and temperature. Non-manned online monitoring and fault diagnosis system of the ozone generator is studied. The simple and feasible structure meets the requirement on the non-manned real-time and accurate monitoring.

  • 【文献出处】 电气自动化 ,Electrical Automation , 编辑部邮箱 ,2014年01期
  • 【分类号】TQ123.2
  • 【被引频次】2
  • 【下载频次】110
节点文献中: 

本文链接的文献网络图示:

本文的引文网络