原子荧光法测定生活饮用水中汞

Determination of mercury in drinking water by atomic fluorescence method

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈志娟余莹冰

【Author】 CHEN Zhi-juan,YU Ying-bing Laboratory,Shantou Center for Disease Control and Prevention,Shantou Guangdong 515041,China

【机构】 汕头市疾病预防控制中心检验科

【摘要】 目的采用氢化物发生-原子荧光光谱法测定生活饮用水中的汞。方法采用2%硝酸溶液作为载流代替原来的5%盐酸溶液,20 g/L的硼氢化钾溶液作为实验的还原剂。结果本方法适用于生活饮用水中汞的测定,回收率90.0%~100.5%,标准曲线r>0.995,检出限为0.033 8μg/L,相对标准偏差为1.24%。结论本方法方便、快速、准确,灵敏度高,能消除实验中的干扰因素,满足日常生活水质的检测要求。

【Abstract】 Objective To determine the mercury of drinking water by hydride generation-atomic fluorescence spectrometry.Methods 2% nitric acid solution was used as a carrier instead of the original 5% hydrochloric acid solution;20 g/L of potassium borohydride solution was a reducing agent for experimental.Results The method was suitable for the determination of mercury in drinking water.The recovery rate was 90.0%-100.5%,the standard curve was above 0.995,the detection limit was 0.033 8 μg/L,standard deviation was 1.24%.Conclusion The method is convenient,rapid and accurate.It can eliminate the interference factors in the experiment and satisfy the detection requirements of the water quality of daily life.

  • 【文献出处】 中国卫生工程学 ,Chinese Journal of Public Health Engineering , 编辑部邮箱 ,2013年01期
  • 【分类号】R123.1;O657.31
  • 【被引频次】4
  • 【下载频次】168
节点文献中: 

本文链接的文献网络图示:

本文的引文网络