节点文献

钼靶X线与超声对乳腺影像报告与数据系统(BI-RADS)Ⅲ~Ⅳ级乳腺病变的诊断价值

Comparative analysis of BI-RADS Ⅲ-Ⅳ lesions imaging by X-ray mammography and ultrasound

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 雷瑞美叶晓青董旭霞童嘉毅

【Author】 LEI Ruimei1 YE Xiaoqing1 DONG Xuxia2 TONG Jiayi3 1.Department of Radiology,Maternal and Child Health Hospital of Lishui City in Zhejiang Province,Lishui 323000,China;2.Department of Radiology,TCM Hospital of Shaoxing City in Zhejiang Province,Shaoxing 312000,China;3.Southeast University,Nanjing 210018,China

【机构】 浙江省丽水市妇幼保健院放射科浙江省绍兴市中医院放射科东南大学

【摘要】 目的探讨钼靶X线与超声对乳腺影像报告与数据系统(BI-RADS)Ⅲ~Ⅳ级乳腺病变的诊断价值。方法对我院2010年1月~2012年12月经术后病理证实的100例BI-RADSⅢ~Ⅳ级女性乳腺肿块患者的钼靶X线及超声检查的资料进行回顾性分析,总结两种方法在影像学诊断中的特点。结果 100例乳腺肿块患者120个病灶,74个为BI-RADSⅢ级,良性57个,占77.03%;恶性17个,占22.97%;46个为BI-RADS IV级,良性7个,占15.22%,恶性39个,占84.78%。钼靶X线图像以片状致密影、结节状影、肿块影、钙化影以及致密模糊结节影为主要的临床表现,其阳性诊断率为77.5%,正确率为78.3%,误诊率11.7%,漏诊率10.0%;而超声图像主要液性、混合性、实质性、边界清晰或不清等局限性病变为主,其阳性诊断率为91.7%,正确率为75.0%,误诊率14.2%,漏诊率10.8%。而超声和钼靶X线联合检查,阳性诊断率为95.8%,正确率92.5%,误诊率4.2%,漏诊率3.3%。两者联合检查的阳性率以及准确率均高于二者单独检查(P<0.05);且误诊率和漏诊率明显低于单独检查(P<0.05)。结论钼靶X线联合超声检查可以互补各自的缺点,大大提高BI-RADSⅢ~Ⅳ级乳腺疾病的检出率,提高阳性诊断率,从而避免因漏诊给患者带来不利的影响。

【Abstract】 Objective To investigate the application value of breast imaging reporting and data system(BI-RADS) ⅢⅣ lesions by X-ray mammography and/or ultrasound.Methods 100 patients in our hospital from January 2010 to December 2012 with BI-RADS Ⅲ-Ⅳ lesions confirmed by pathological diagnosis were enrolled.All of them underwent clinical examination,mammography and ultrasound,summarized radiographic features of mammography and ultrasound.Results 100 patients had 120 lesions.74 BI-RADS Ⅲ,57 benign,accounting for 77.03%;vicious 17,accounting for 22.97%;46 BI-RADS Ⅳ,7 benign,accounting for 15.22%,malignant 39,accounting for 84.78%.Molybdenum target X-ray image performance to flake opacities,nodules,lumps shadow,calcification and dense fuzzy nodules,positive diagnosis was 77.5%,accuracy was 78.3%,misdiagnosis rate was 11.7%,the rate of misdiagnosis was 10.0%;ultrasound images mainly restricted lesions,fluid,mixed,materiality,the boundary clear or unclear,the positive diagnosis was 91.7%,the correct rate of 75.0%,the rate of misdiagnosis 14.2%,misdiagnosis rate of 10.8%.Ultrasound and mammography X-ray of the Joint Inspection positive diagnosis was 95.8%,accuracy rate was 92.5%,the misdiagnosis rate of 4.2%,3.3% of the rate of misdiagnosis.Joint Inspection of both positive rate and the accuracy rate is higher than the two separate checks,P < 0.05;misdiagnosis and missed diagnosis rate was significantly lower than the two separate checks(P < 0.05).Conclusion It is demonstrated that the mechanism of mammography and ultrasound imaging are different.Combination of the two approaches could improve the BI-RADS Ⅲ-Ⅳ detection rate and accuracy of differential diagnosis between benign and malignant lesion.

【关键词】 乳腺肿瘤超声检查钼靶X线检查
【Key words】 Breast lumpsUltrasoundX-ray mammography
【基金】 高等学校博士学科点专项科研基金(20090092120059)
  • 【文献出处】 中国现代医生 ,China Modern Doctor , 编辑部邮箱 ,2013年24期
  • 【分类号】R655.8
  • 【被引频次】4
  • 【下载频次】66
节点文献中: 

本文链接的文献网络图示:

本文的引文网络