【摘要】 目的建立反相高效液相色谱(RP-HPLC)法测定人体血浆中伊洛哌酮的含量。方法色谱柱为美国Diamonsil(?)C18反相柱(250mm×4.6mm,5μm),流动相为乙腈-甲醇-缓冲液(40:55:5,V/V/V),流速为1.0 mL·min-1,柱温35℃,检测波长280 nm。结果伊洛哌酮血浆质量浓度在0.0212.688 mg·L-1范围内线性关系良好(r=0.998 9),平均相对回收率为98.21%,平均日间精密度为6.02%。结论本法快速、简便、准确,适于伊洛哌酮药动学研究和临床监测。
【Abstract】 AIM To establish a RP-HPLC method for content determination of iloperidone in human plasma.METHODS A Diamonsil C18 column(250 mm×4.6 mm,5 μm) was used with mobile phase of acetonitrile-methanol-buffer(40:55:5,V/V/V).Flow rate was 1.0 mL·min-1,column temperature was 35℃.UV detection wavelength was 280 nm.RESULTS Within a mass concentration range of 0.021-2.688 mg·L-1,standard curve of iloperidone had a good linearity(r = 0.998 9).The average relative recovery was 98.21%,and the average daytime precision was 6.02%.CONCLUSION This method is rapid,convenient and accurate.It can be used for the pharmacokinetics study and clinical monitor of iloperidone.
【Key words】 iloperidone; chromatography,high pressure liquid; plasma; content;