节点文献

胆囊癌多b值磁共振扩散加权成像的临床应用

Clinical usefulness of multiple b values of diffusion-weighted MR imaging for detection of gallbladder cancer

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 蔡崧崔兴宇王国祥孟祥鸿王成达蒋兆贯顾光官

【Author】 CAI Song;CUI Xing-yu;WANG Guo-xiang;MENG Xiang-hong;WANG Cheng-da;JIANG Zhao-guan;Gu Guang-guan;Department of Radiology,Traditional Chinese Medicine Hospital of Wuxi;Department of Radiology,Wuxi People’s Hospital,Nanjing Medical University;

【机构】 江苏省无锡市中医医院放射科南京医科大学附属无锡人民医院影像科

【摘要】 目的评价不同b值磁共振扩散加权成像对胆囊癌的显示能力和最佳b值的选择;并探讨表观扩散系数值与胆囊癌分化程度的关系。方法对33例胆囊癌患者术前行常规MRI和DWI检查。测量肿瘤的ADC值,计算多b值扩散成像和T2WI图像中的信噪比、对比噪声比及信号强度比等数据;对经手术病理证实的33例胆囊癌患者进行病理分级,比较不同b值时不同分化程度胆囊腺癌的ADC值;并进行统计学分析。结果 33例胆囊癌病灶均被DWI检出,肿瘤的SNR和肿瘤与正常肝脏的CNR随b值的增加逐渐下降,而肿瘤的SIR随b值增加逐渐升高。b值800s/mm2时DWI图像肿瘤与正常肝脏的CNR、肿瘤的SIR和SNR均高于T2WI,差异有统计学意义(P<0.05)。胆囊腺癌的ADC值随着b值增高逐渐变小,差异有统计学意义(P<0.05)。结论胆囊癌扩散加权成像的最佳b值为800s/mm2,可以得到胆囊癌的良好显示;胆囊腺癌ADC值随着肿瘤分化程度的降低而减小。

【Abstract】 Objective To measure the sensitivity of diffusion-weighted imaging,determine the most appropriate b value for DWI and also,to explore the correlation between the apparent diffusion coefficient to and the degree of gallbladder cancer differentiation.Methods Preoperative diffusion-weighted imaging and magnetic resonance examinations were performed for 33patients with gallbladder cancer.Tumor ADC values were measured,and the signal-to-noise ratio,contrastto-noise ratio,and signal-intensity ratio between the diffusion-weighted images with various b values as well as the T2-weighted images were calculated.33patients pathologically confirmed were pathologically graded to compare the ADC value with different b values of tumor at different degrees of differentiation,and the results were statistically analyzed.Results All 33cases of gallbladder cancer were detected by DWI.As the b value increased,tumor signal-to-noise ratio and contrast-to-noise ratio between the tumor and normal liver gradually decreased,but the tumor signal-intensity ratio gradually increased.When b=800s/mm2,contrast-to-noise ratio between tumor and normal liver,tumor signal-intensity ratio, and tumor signal-noise ratio of diffusion-weighted images were all higher than those of T2-weighted images;the differences were statistically significant(P <0.05).As the b value increased,the tumor ADC value gradually declined.As the degree of differentiation decreased,the tumor ADC value declined.Conclusion The b value of 800s/mm2was the best in DWI of gallbladder cancer;the lesion ADC value declined as the degree of cancerous tissue differentiation decreased.

【基金】 江苏省自然科学基金项目(编号:BK2012541);无锡市科技支撑-社会发展计划(编号:CSE01N1213);无锡市医院管理中心医学技术重大项目(编号:YGZF1103)
  • 【文献出处】 医学影像学杂志 ,Journal of Medical Imaging , 编辑部邮箱 ,2013年10期
  • 【分类号】R445.2
  • 【被引频次】9
  • 【下载频次】79
节点文献中: 

本文链接的文献网络图示:

本文的引文网络