水中氰化物应急监测方法研究

Study of emergency analysis method of cyanide in water

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 朱东方白静曲春浩胡延光王军

【Author】 ZHU Dong-fang;BAI Jing;QU Chun-hao;HU Yan-guang;WANG Jun;Department of Applied Chemistry,Henan Vocational College of Chemical Technology;Shaanxi Research Design Institute of Petroleum and Chemical Industry;

【机构】 河南化工职业学院应用化学系陕西省石油化工研究设计院

【摘要】 研究现场快速测定水中氰化物的应急监测方法。运用HANNA C200多参数离子计现场快速测定了水中氰离子,其线性范围为0.001~0.50 mg/L,检出限0.001 mg/L,对测定准确度、精密度进行分析,氰离子测定总变异系数为2.63%,小于5%,回收率在90.6%~95.1%,该法具有快速、简便、准确度高等优点,适于水中氰化物的快速测定。

【Abstract】 Cyanide in water need be rapidly detected.A simple,rapid method for detecting cyanide in water is described with HANNA C200.The accuracy and precision of the determination are analyzed.The liner range was 0.001 ~ 0.50 mg / L.The average recoveries of cyanide ranged from 90.6% ~ 95.1%.The coefficient of variation is 2.63% which is less than 5%.The result indicate that the method is simple,rapid,accurate and fit for the rapid determination of cyanide in water.

【关键词】 水中氰化物应急监测光度法
【Key words】 cyanideemergency analysisabsorption spectrum
【基金】 陕西省科技攻关项目(2009k01-42)
  • 【文献出处】 应用化工 ,Applied Chemical Industry , 编辑部邮箱 ,2013年10期