节点文献

聚对氨基苯磺酸修饰电极差分脉冲伏安法测定抗坏血酸

Differential Pulse Voltammetric Determination of Ascorbic Acid on Polyp-Aminobenzene Sulfonic Acid Modified Electrode

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 韩俊凤蔡雪何柳

【Author】 HAN Jun-feng;CAI Xue;HE Liu;Department of Chemistry and Chemical Engineering,Mudanjiang Normal College;

【机构】 牡丹江师范学院化学化工学院

【摘要】 采用循环伏安法在玻碳电极上通过电化学聚合制备了聚对氨基苯磺酸修饰玻碳电极(PABSA/GCE)。与裸玻碳电极相比,在pH 5.0的磷酸盐缓冲溶液中,抗坏血酸在0.069V产生一个灵敏的氧化峰,表明修饰电极对抗坏血具有明显的电催化氧化作用。在优化的试验条件下,抗坏血酸的质量浓度在1.2~320mg·L-1范围内与氧化峰电流呈线性关系,检出限(3S/N)为0.4mg·L-1。以维生素C片作为基体用标准加入法做回收试验,测得结果在98.1%~105%之间。

【Abstract】 Poly-p-aminobenzene sulfonic acid was modified on glassy carbon electrode by cyclic voltammetric electropolymerization,which was abbreviated as PABSA/GCE.In comparison with the bare GCE,a significant oxidation peak of ascorbic acid at the modified electrode in PBS of pH 5.0was observed.It was found that the modified electrode exhibited excellent electrocatalytic responses towards the oxidation of ascorbic acid.Under the optimized conditions,linear relationship between values of oxidation peak current and mass concentration of ascorbic acid was kept in the range of 1.2-320mg·L-1 with detection limit(3S/N)of 0.4mg·L-1.Test for recovery was made by standard addition method using VC tablets as matrix,giving results in the range of 98.1%to 105%.

【基金】 牡丹江师范学院青年学术骨干项目(G201208);
  • 【文献出处】 理化检验(化学分册) ,Physical Testing and Chemical Analysis(Part B:Chemical Analysis) , 编辑部邮箱 ,2013年08期
  • 【分类号】O657.1
  • 【被引频次】2
  • 【下载频次】133
节点文献中: 

本文链接的文献网络图示:

本文的引文网络