节点文献

高温后钢筋混凝土短柱抗震性能试验研究

Experimental study on seismic performance of reinforced concrete short columns after fire

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 徐玉野杨清文吴波徐明

【Author】 XU Yuye 1,2,YANG Qingwen 1,WU Bo 2,XU Ming 3(1.College of Civil Engineering,Huaqiao University,Xiamen 361021,China;2.State Key Laboratory of Subtropical Building Science,South China University of Technology,Guangzhou 510640,China;3.College of Civil Engineering,Southeast University,Nanjing 210096,China)

【机构】 华侨大学土木工程学院华南理工大学亚热带建筑科学国家重点实验室东南大学土木工程学院

【摘要】 通过对7根高温后钢筋混凝土短柱试件和1根常温对比试件的拟静力试验,研究受火时间、轴压比和剪跨比对火灾后钢筋混凝土短柱的破坏形态、受剪承载力、骨架曲线、刚度退化、延性比、滞回耗能等的影响。利用有限元程序计算了高温后截面混凝土抗压强度的平均折减系数,提出了四周受火后钢筋混凝土柱受剪承载力的计算方法。研究结果表明:高温后短柱的受剪承载力随受火时间的增加、剪跨比的增大而减小;剪跨比对受火前后受剪承载力影响变化的程度相差较小;高温后短柱的受剪承载力先随轴压比的增大而增大,但当轴压比增大至界限轴压比后,受剪承载力反将降低,且高温后柱的界限轴压比较未受火时有减小趋势;提出的高温后钢筋混凝土柱受剪承载力计算式具有一定的安全保证率,可用于火灾后该类构件受剪性能的损伤评定。

【Abstract】 Based on the quasi-static tests of seven reinforced concrete(RC) short columns after fire and one contrastive specimen at ambient temperature,the effects of fire exposure time,axial load ratio and shear span ratio on the failure mode,shear strength,skeleton curve,stiffness degradation,ductility ratio and hysteretic energy were analyzed.The average reduction coefficient of compressive strength in concrete sections was calculated by a finite element program,and a practical calculation method for the shear strength of RC columns after exposure to fire on all sides was proposed.The results show that: the shear strength of short columns decreases with the increase of fire exposure time and shear span ratio.The difference of influence degree of shear span ratio on the shear strength of columns before and after fire is small.With an increase of axial load ratio,the shear strength of short column after fire firstly is increased and then decreasing.The critical value of the influence of axial load ratio on the shear strength of columns after fire is less than that at ambient temperature.The proposed formula for the residual shear capacity of RC columns after fire has certain safety margin ratio,and can be used to assess the shear performance of that member after fire.

【基金】 国家自然科学基金项目(50908091);国家重点基础研究发展计划(973计划)项目(2011CB013800);福建省自然科学基金项目(2012J01221);福建省高等学校杰出青年科研人才培育计划项目(JA10005)
  • 【文献出处】 建筑结构学报 ,Journal of Building Structures , 编辑部邮箱 ,2013年08期
  • 【分类号】TU375.3;TU352.11
  • 【被引频次】44
  • 【下载频次】735
节点文献中: 

本文链接的文献网络图示:

本文的引文网络