节点文献

流动注射光度法测定海水中可溶性硅酸盐

Flow injection spectrophotometic method for determination of soluble silicates in seawater

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王丽平赵萍

【Author】 WANG Li-ping,ZHAO Ping(Beijing Titan Instruments Co.,Ltd.,Beijing 100015,China)

【机构】 北京吉天仪器有限公司

【摘要】 采用流动注射分光光度法,快速准确测定海水中可溶性硅酸盐SiO23-,该方法很好的解决了测定过程中海水盐度干扰的问题。在优化好的试验条件下,方法检出限为2.84μg/L SiO23-,SiO23-浓度在50.0~2 000.0μg/L具有良好的线性关系(相关系数0.999 9),500μg/L样品的RSD为0.65%(n=7),实际海水样的加标回收率为92.4%~98.4%,检测频率为32样/h。

【Abstract】 A Flow injection spectrophotometic method was applied to determine soluble silicates rapidly and exactly in seawater,the problem of sea water salinity interference was solved in the process of determination of soluble silicates in seawater.Under the optimum conditions,the detection limit was 2.84 μg/L SiO2-3with the linear range of 50.0~2 000.0 μg/L(r=0.999 9).The precision(500 μg/L,n=7) and recovery were 0.65% RSD and 92.4%~98.4% respectively.The detection frequency was 32 samples/h.

【基金】 北京市朝阳区高新技术产业发展计划项目(GX1014)
  • 【文献出处】 海洋环境科学 ,Marine Environmental Science , 编辑部邮箱 ,2013年02期
  • 【分类号】X834
  • 【被引频次】3
  • 【下载频次】142