微波消解-原子荧光光谱法测定大气PM2.5中的砷
Determination of Arsenic in Atmospheric Fine Particulates PM2. 5 by Microwave Digestion and Atomic Fluorescence Spectroscopy
【摘要】 采用微波消解-原子荧光光谱法测定大气细颗粒物中的砷,确定了最佳样品处理方法与测定条件。方法在0μg/L~40.0μg/L范围内线性良好,标准曲线相关系数达0.999以上,检出限为0.01μg/L。土壤标准品的测定值在标准值范围内,大气PM2.5滤膜样品加标回收率为96.0%~102%,5次平行测定的RSD为1.5%~3.6%。
【Abstract】 Samples of atmospheric fine particulates was digested by microwave,and arsenic was determined by hydride generation-atomic fluorescence spectroscopy( AFS). The experimental conditions for treating and analyzing samples were optimized. The correlation coefficient of standard curve could reach more than 0. 999 between 0 μg / L ~ 40. 0 μg / L,and the detection limit was 0. 01 μg / L. The analysis results of national soil standard materials were all within standard value ranges. The recovery rate of standard addition in the sample was in the range of 96% to 102%. RSD of result by the five parallel determination was 1. 5% to 3. 6%.
【Key words】 Arsenic; Atomic fluorescence spectroscopy; Microwave digestion; PM2.5;
- 【文献出处】 环境监测管理与技术 ,The Administration and Technique of Environmental Monitoring , 编辑部邮箱 ,2013年06期
- 【分类号】X831;O657.31
- 【被引频次】1