节点文献

吹扫捕集-气相色谱/质谱法测定饮用水中四乙基铅

Determination of Tetraethyl Lead in Drinking Water by Purge and Trap-gas Chromatography/mass Spectrometry

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张秦铭周弛马文鹏和莹李合义白昭杜新黎

【Author】 Zhang Qinming;Zhou Chi;Ma Wenpeng;He Ying;Li Heyi;Bai Zhao;Du Xinli;Shaanxi Environmental Monitoring Centre;The northwest centre of national environmental dioxin monitoring centre;

【机构】 陕西省环境监测中心站国家环境二噁英监测中心西北分中心

【摘要】 文章讨论了饮用水中四乙基铅吹扫捕集-气相色谱/质谱分析方法,对捕集条件进行了优化,并对方法检出限、线性范围、精密度和准确度等进行了测定,对实际水样进行了测试。结果显示,方法检出限为0.02 g/L;在0.10~15.0 g/L之间具有良好的线性,线性相关系数为0.9991;加标回收率为87%~108%;连续7次测定的相对标准偏差为7.5%。该方法非常适用于测定水中痕量的四乙基铅。

【Abstract】 In this paper,the determination of tetraethyl lead in drinking water was investigated by purge and trap-gas chromatography/mass spectrometry. Many factors of the purge and trap method were optimized. The method detection limit,linear calibration range,precision and accuracy were investigated respectively. Finally,the actual aqueous samples were determined using this method. The results show that,the method detection limit is 0.02 μg/L; the calibration graph is linear in the range of 0.10~15.0 μg/L,with the correlation coefficients of 0.9991; the recoveries of this method are 87 %~108 %; the relative standard deviations of seven times determination are 7.5 %. And this method is very efficient for determination of trace amounts of tetraethyl lead in aqueous samples.

【基金】 Pb污染诊断和表征体系建立及防控区域划分技术研究,项目编号:201109053-04
  • 【文献出处】 广东化工 ,Guangdong Chemical Industry , 编辑部邮箱 ,2013年24期
  • 【分类号】X832
  • 【被引频次】1
  • 【下载频次】63
节点文献中: 

本文链接的文献网络图示:

本文的引文网络