节点文献
基于牵引负荷的三相不平衡度计算方法比较
Comparison of Different Calculation Methods for Three-phase Voltage Unbalance Based on Measured Traction Load
【摘要】 三相电压不平衡度是电力系统评估的一个重要指标,不同的国家和地区有不同的计算标准。铁路牵引负荷是一个特殊的用电负荷-单相电力负荷,具有单相独立性和不对称性。文中针对实测的牵引负荷数据,用国内外不同的电压不平衡度计算标准对同一实测数据进行计算,得出5种不同计算标准下电铁电压不平衡度的区别和相关性,便于工程技术人员针对此特殊的供电负荷,选择合适的电压不平衡度计算方法。
【Abstract】 The three-phase voltage unbalance degree is an important index for power system evaluation. Different countries and regions have different calculation standards. Traction load is a special electrical load,a single-phase electric power load with single phase independence and asymmetry. According to the measured data of the traction’s load,this paper takes different calculation methods for calculating three-phase voltage unbalance degree. The differences and the correlations of the five different calculation methods can be obtained,which can be used for engineers and technicians to choose the proper calculation method for the special electrical load to calculate its three-phase voltage unbalance degree.
【Key words】 power system; traction load; voltage unbalance; correlation;
- 【文献出处】 电力系统及其自动化学报 ,Proceedings of the CSU-EPSA , 编辑部邮箱 ,2013年06期
- 【分类号】TM922.3;TM744
- 【被引频次】8
- 【下载频次】239