节点文献

双抗体间接夹心ELISA法检测血清MUC1蛋白方法的建立及其在肺癌诊断中的应用

Establishment of indirect sandwich ELISA method for serum MUC1 detection and its application in diagnosis of lung cancer

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 何秋立张旭王娟翟瑞萍乔彩霞孙霞霞倪维华高素君台桂香

【Author】 HE Qiu-li1,ZHANG Xu2,WANG Juan2,ZHAI Rui-ping2,SUN Xia-xia2,QIAO Cai-xia1, NI Wei-hua2,GAO Su-jun1,TAI Gui-xiang2(1.Tumor Center,First Hospital,Jilin University,Changchun 130021,China; 2.Department of Immunology,Norman Bethune College of Medicine,Jilin University,Changchun 130021,China)

【机构】 吉林大学第一医院肿瘤中心吉林大学白求恩医学院免疫学教研室

【摘要】 目的:建立双抗体间接夹心酶联免疫吸附法(ELISA)试剂盒,检测血清黏蛋白1(MUC1)水平,探讨其在肺癌诊断中的应用,阐明血清MUC1蛋白检测的临床应用价值。方法:在前期制备的MUC1蛋白和兔抗人MUC1多克隆抗体的基础上,建立以鼠抗人MUC1单克隆抗体为包被抗体,兔抗人MUC1多克隆抗体为检测抗体的双抗体间接夹心ELISA方法,并通过对MUC1蛋白标准品的检测,绘制出标准曲线。临床上收集48例肺癌患者、7例肺良性疾病患者和20例健康人的血清,应用本研究建立的ELISA方法检测各组标本血清MUC1蛋白表达水平,绘制ROC曲线,确定最佳cut-off值,得出双抗体间接夹心ELISA方法检测肺癌的敏感度、特异度及约登指数。同时与临床应用的CA15-3试剂盒检测结果进行比较。结果:应用双抗体间接夹心ELISA法确定血清MUC1的临界值为1.98μg.L-1,检测肺癌的敏感度为62.5%,特异度为100%,约登指数为0.625 0。CA15-3试剂盒检测肺癌的敏感度为18.75%,特异度为100%,约登指数为0.187 5。结论:建立的双抗体间接夹心ELISA试剂盒检测肺癌有更高的敏感度和特异度,优于临床常用的CA15-3试剂盒。

【Abstract】 Objective To establish an indirect sandwich enzyme-linked immunesorbent assay(ELISA) kit for detecting serum level of mucin 1(MUC1) protein and to explore its application in diagnosis of lung cancer,and to reveal the value of MUC1 protein detection in clinic.Methods With rabbit anti-human MUC1 monoclonal antibodies and rat anti-MUC1 polyclonal antibodies as coating antibodies and testing antibodies,respectively,a new ELISA method was developed in this study,and the standard curve was gotten.Then,the serum MUC1 levels in the peripheral blood of 48 cases with lung cancer,7 cases with lung benign diseases,and 20 healthy subjects were detected with indirect ELISA.The optimal cut-off value,the specificity,the sensitivity and the Youden index were determined with ROC curve analysis.At the same time,the serum levels of MUC1 detected by CA15-3 commercial kits were analyzed.Results Based on indirect sandwich ELISA,the cut-off value for serum MUC1 was 1.98 μg·L-1,the sensitivity was 62.5%,the specificity was 100% and the Youden index was 0.6250.While based on the CA15-3 kit,the sensitivity was 18.75%,the specificity was 100% and the Youden index was 0.187 5.Conclusion The indirect ELISA kit is superior to the CA15-3 kit in detecting MUC1 in lung cancer.

【基金】 国家自然科学基金资助课题(30972782);吉林省自然科学基金资助课题(201115049);“重大新药创制”科技重大专项资助课题(2011ZX09102-001-36)
  • 【文献出处】 吉林大学学报(医学版) ,Journal of Jilin University(Medicine Edition) , 编辑部邮箱 ,2013年02期
  • 【分类号】R392.1
  • 【被引频次】1
  • 【下载频次】263
节点文献中: 

本文链接的文献网络图示:

本文的引文网络