湿法消化-原子荧光光谱法测定食品中碲

Determination of tellurium in food by wet digestion-atomic fluorescence spectrometry

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 范华锋陈辉袁金华

【Author】 FAN Hua-feng,CHEN Hui,YUAN Jin-hua(Nanjing Municipal Centre for Disease Control and Prevention,Nanjing 210003,China)

【机构】 江苏省南京市疾病预防控制中心

【摘要】 目的:建立湿法消化和氢化物发生—原子荧光光谱法测定食品中碲的方法。方法:采用湿法消化,优化仪器条件,比较不同溶液酸度效果,考察常见干扰离子对测定的影响,利用氢化物发生—原子荧光光谱法测定食品中碲。结果:采用本方法测定,碲的线性范围为0μg/L~2μg/L,r=0.9999,DL=0.035μg/L,回收率为98.4%~104.2%,精密度(RSD%)为2.55。结论:实验方法简单快捷,结果准确,满足测定要求,适合于食品中碲的测定。

【Abstract】 Objective:To establish a method for determination of tellurium in food by atomic fluorescence spectrometry after wet digestion.Methods: After using wet digestion,optimizing instruments conditions,comparing the effect of different pH,and exploring the influence of interfering ions,tellurium in food was determined by hydride generation-atomic fluorescence spectrometry.Results: The linear calibration curve for tellurium was within the range of 0 μg/L~2 μg/L with correlative coefficient of 0.9999.The detection limit was 0.035 μg/L for tellurium.The recovery rates of spiking standards for tellurium was in the range of 98.4%~104.2%,respectively.The RSD was 2.55% for tellurium.Conclusion: The method is simple,accurate and rapid enough for determination of tellurium in food.

  • 【文献出处】 中国卫生检验杂志 ,Chinese Journal of Health Laboratory Technology , 编辑部邮箱 ,2012年12期
  • 【分类号】O657.31;TS207.5