【摘要】 目的探讨呼吸机螺纹管消毒后保存的有效期限。方法将复用呼吸机螺纹管使用-清洗-消毒后随机分为:A组自然晾干法、B组95%乙醇冲洗干燥法、C组烘干箱烘干法,分别在不同的保存时间内进行了576次螺纹管内表面采样后细菌学检测。结果消毒后保存7、14、21、28d采样检测阳性率分别为:A组6.12%、24.00%、12.77%、13.33%,B组6.00%、6.25%、2.50%、4.00%,C组0、0、2.17%、0;不合格率分别为:A组6.12%、6.00%、8.51%、11.11%,B组0、0、2.50%、4.00%,C组在不同时间内无不合格样本;不合格样本均在潮湿季节内。结论潮湿季节不能采用自然晾干法;95%乙醇冲洗法干燥保存的呼吸机螺纹管,在<14d达到消毒合格;烘干箱烘干法干燥保存的呼吸机螺纹管不受季节的影响,14d无菌生长,28d保持消毒合格。

【Abstract】 OBJECTIVE To explore the validity period of ventilator pipe after disinfection.METHODS After cleaning and disinfection,the re-used threaded pipes from breathing machine were randomly divided into 3 groups,and different drying methods were applied including:(A) natural drying method,(B) 95% alcohol rinse drying,(C) oven drying method.576 bacteriological tests were performed after sampling from threaded inner surface at different time points of preservation.RESULTS After disinfection and preservation for 7 d,14 d,21 d and 28 d,positive rates detected in group A were : 6.12%,24.00%,12.77% and 13.33% respectively,in group B were 6.00%,6.25%,2.50% and 4.00%,and in group C were 0%,0%,2.17% and 0%.The failure rates were:6.12%,6.00%,8.51% and 11.11% in group A,0%,0%,2.50% and 4.00 % in group B,there was no unsatisfactory sample in group C at any of the test time points.Unsatisfactory samples were all detected in wet season.CONCLUSION Natural drying method can not be used in wet season;for ventilator pipe preserved after 95% alcohol rinse drying,acceptable disinfection can be maintained for 14 days;ventilator pipe preserved after oven drying was not influenced by season,no bacterial growth within 14 days and the acceptable disinfection can be maintained for 28 days.

【关键词】 呼吸机螺纹管消毒保存时间
【Key words】 Ventilator pipeDisinfectionPreservation time
  • 【文献出处】 中华医院感染学杂志 ,Chinese Journal of Nosocomiology , 编辑部邮箱 ,2012年01期
  • 【分类号】R187
  • 【被引频次】8
  • 【下载频次】96
节点文献中: 

本文链接的文献网络图示:

本文的引文网络