电感耦合等离子体原子发射光谱仪器的安装准备及故障判别

Solution for Outstanding Preparation of Installation, General Troubleshooting and Common Testing Problems of ICP-OES

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 戴亚明

【Author】 Dai Yaming(Testing Center for Shanghai Research Institute of Materials,Shanghai,200437)

【机构】 上海材料研究所检测中心

【摘要】 随着电感耦合等离子体发射光谱的广泛普及应用,本文对仪器的主要的安装准备工作,常见的仪器硬件和软件故障及其检测上的共性问题进行了叙述研讨。这些问题的解决或依赖仪器公司的技术支持或仪器硬件的维修人员或懂化学分析并使用仪器经验丰富的客户;有时或许要集中这三者的智慧。本文抛砖引玉,期望互相讨论,取长补短。

【Abstract】 With the popularity and application of ICP-AES widely,the outstanding points of installation preparations,common instrument hardware/software malfunctions,as well as the general testing problems are described and discussed within this article.The solution to those problems depends on instrument companies which provide technical support,maintainers who is responsible for hardware,or experienced clients who know how to perform chemical analysis.Sometimes it may require all of the above three conditions.The purpose of this article is to draw more constructive comments.Hopefully there would be more discussions among the spectrum industry,in order to get more improvements.

  • 【文献出处】 现代科学仪器 ,Modern Scientific Instruments , 编辑部邮箱 ,2012年06期
  • 【分类号】TH744.1
  • 【被引频次】4
  • 【下载频次】187