血液白细胞图像自动识别系统开发与应用
Development and application of automatic recognition system for leukocyte images
【摘要】 目的:开发并应用血液白细胞图像自动识别系统。方法:运用数据挖掘、模式识别和人工智能等技术,并与手工显微镜分类计数法(参考方法)比较。结果:白细胞图像自动识别系统的准确率为94.9%,重复率为0.1%,漏检率为0.6%,稳定性达到97.6%,检测速度低于5min/片。与手工显微镜分类法的相关系数:中性粒细胞为0.997 1,淋巴细胞为0.994 2,嗜酸性粒细胞为0.989 9,单核细胞的相关系数为0.982 2,嗜碱性粒细胞为0.852 8,其他细胞为0.979 8。结论:研制的血液白细胞图像自动识别系统的检测结果与手工显微镜分类计数法相近,能够满足临床要求。
【Abstract】 Objective: To develop and apply automatic recognition system of leukocyte images.Methods: Data mining,pattern recognition,artificial intelligence and other techniques were applied to design this new system.Its accuracy,repeatability error,omission error,reliability,detection rate and correlation coefficients were evaluated according to manual differential counts(reference method).Results: The accuracy is 94.9%;repeatability error is 0.1%;omission error is 0.6%;reliability is 97.6%and detection rate is below 5 minutes per slide respectively.The correlation coefficients are the highest for neutrophils(0.997 1),lymphocytes(0.994 2) and eosinophils(0.989 9).For monocytes,the correlation coefficient is 0.982 2.The lowest correlations are basophils(0.852 8) and other cells(0.979 8).Conclusion: The evaluation shows this system has performance at least equal to that of direct clinical microscopy and could meet the clinical demand.
【Key words】 leukocyte differential; image analysis; automatic recognition; performance evolution;