新型肝素化聚氨酯涂层三氧化二砷洗脱支架的初步研究

Preliminary study on arsenic trioxide eluting stent with a heparin-immobilized polyurethane coating

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陆跃沈雳龚飞荣饶炬陈建定田文杰吴轶喆张峰杨巍葛均波

【Author】 LU Yue,SHEN Li,GONG Feirong,RAO Ju,CHEN Jianding,TIAN Wenjie,WU Yizhe,ZHANG Feng,YANG Wei,GE Junbo.Key Laboratory for Ultrafine Materials of Ministry of Education,School of Material Science and Engineering,East China University of Science and Technology,Shanghai 200237,China

【机构】 华东理工大学材料科学与工程学院,超细材料制备与应用教育部重点实验室复旦大学附属中山医院心内科,上海市心血管病研究所

【摘要】 目的研究新型三氧化二砷洗脱支架(AES)的涂层材料的生物相容性及其药物释放的特征及初步功效。方法以肝素化聚氨酯为药物支架涂层材料,三氧化二砷(As2O3)为药物,成功制备新型AES,研究其在(37±0.5)℃、体外磷酸盐缓冲溶液(PBS,pH值=7.4)中的释放规律。在体内比较AES与金属裸支架(BMS)植入4周时的相关组织反应及血管内膜增生的情况,观察支架表面的内皮化进程及内皮功能恢复情况。结果支架所载药物在1周内全部释放。支架植入1周后,AES植入处的冠状动脉平滑肌细胞凋亡率为(62.6±9.6)%,显著高于BMS及单聚合物涂层支架(PCS)植入处的(18.1±3.3)%及(21.2±5.3)%(P值均<0.05)。AES植入处血管的管腔面积较BMS及PCS植入处显著增加(P值均<0.05),而内膜面积、支架内再狭窄(ISR)发生率及内膜厚度均显著减少(P值均<0.05)。支架植入4周后,BMS及AES植入处表面均内皮化完全。以60mg/mL的速度注入乙酰胆碱,BMS、PCS、AES植入处血管的平均收缩率分别为(21.7±4.5)%、(20.4±3.7)%、(23.3±4.2)%,3种支架间的差异无统计学意义(P>0.05)。结论新型聚氨酯涂层的AES具有良好的生物相容性,其药物释放在动物冠状动脉支架植入模型中可有效抑制内膜增生,并具有较好的内皮覆盖性能。该支架的深入研究及优化有望为临床提供一种在减少ISR发生的同时,可降低不良事件发生率的新型内皮友好型支架。

【Abstract】 Objective To evaluate the biocompatibility,drug release and preliminary efficacy of arsenic trioxide(As2O3) eluting stent(AES) with a new heparin-immobilized polyurethane coating.Methods A new AES was successfully developed with heparin-immobilized polyurethane as coating material and As2O3 as the drug.Drug release was measured in phosphate buffered solution(PBS,pH=7.4) at(37±0.5) ℃.In a porcine stent implantation model,the thicknesses and apoptosis of vascular smooth muscle cells(VSMC) as well as stent surface endothelialization and endothelial function were investigated between AES and bare metal stents 4 weeks after stent implantation.Results In vitro As2O3 release study indicated that the drug was totally released within 7 days.The apoptosis rate of VSMC in the coronary arteries with AES was significantly higher than those in BMS and polymer coated stent(PCS) one week after stent implantation([62.6±9.6]%,[18.1±3.3]%,and [21.2±5.3]%,P<0.05).Compared with BMS and PCS,the area of lumen of blood vessel in the coronary arteries with AES was significantly increased,but the area and thickness of endomembrane and in-stent restenosis was significantly decreased(P<0.05).Complete endothelialization on the surface of BMS and AES was achieved 4 weeks after stent implantation.The diameter changes in response to the Ach infusion(60 mg/mL) in sites distal to the stents between BMS,PCS and AES had no significant differences([21.7±4.5]%,[20.4±3.7]% and [20.4±3.7]%,P>0.05).Conclusion The new AES has good biocompatibility and may be a promising endothelial-friendly drug eluting stent.It can effectively inhibit restenosis and reduce adverse events such as late stent thrombosis in porcine model.

【基金】 国家863项目(2007AA02Z450);国家自然基金项目(81101133);上海市科学技术委员会课题(11441900300)资助
  • 【文献出处】 上海医学 ,Shanghai Medical Journal , 编辑部邮箱 ,2012年03期
  • 【分类号】R318.08
  • 【被引频次】3
  • 【下载频次】163
节点文献中: 

本文链接的文献网络图示:

本文的引文网络