【作者】 赵瑛瑛欧阳军王建生张宛哲张文吉孟晶茜申鹏霄刘丁汤建民

【Author】 ZHAO Yingying1),OU Yangjun2),WANG Jiansheng2),ZHANG Wanzhe1),ZHANG Wenji1),MENG Jingqian1),SHEN Pengxiao1),LIU Ding1),TANG Jianmin3) 1)Department of Nephrology,the Second Affiliated Hospital,Zhengzhou University,Zhengzhou 450014 2)Medical Science Research Institute of Henan Province,Zhengzhou 450052 3)Department of Cardiology,the Second Affiliated Hospital,Zhengzhou University,Zhengzhou 450014

【机构】 郑州大学第二附属医院肾内科河南省医药科学研究院郑州大学第二附属医院心血管内科

【摘要】 目的:探讨血清胱抑素C(Cys-C)检测在造影剂肾病(CIN)早期诊断中的意义。方法:采用回顾性研究的方法,选择接受冠状动脉造影术和(或)经皮冠状动脉介入治疗术的冠心病患者为研究对象,收集患者造影前、造影后24h和48h血清Cys-C、血清肌酐等相关临床资料,比较血清Cys-C与Scr检测在造影剂肾病早期诊断的特异性和敏感度。结果:与造影前[(1.03±0.18)mg/L]比较,427例研究对象造影后24h[(1.27±0.21)mg/L]和48h[(1.31±0.26)mg/L]血清Cys-C升高,差异有统计学意义(F=39.542,P=0.031)。以血清肌酐变化为诊断指标,造影后24h和48hCIN的发生率分别为6.57%和7.20%,均低于以血清Cys-C法诊断标准下CIN的发生率(10.17%和10.81%,χ2=262.359和236.669,P均<0.001)。运用血清Cys-C法在造影后24h诊断CIN的灵敏度和特异度分别为96.77%和95.92%,造影后48h为91.18%和95.43%。结论:Cys-C可敏感地反映造影剂肾毒性程度,有利于造影剂肾病的早期诊断。

【Abstract】 Aim:To study the value of detecting serum cystatin C(Cys-C) in early diagnosis of contrast induced nephropathy(CIN).Methods:Taking retrospective analysis method,a total of 427 patients undergoing diagnostic coronary angiography or percutaneous coronary intervention were enrolled.Serum Cys-C,serum creatinine(Scr) and other relevant clinical data of the patients were collected before imaging and 24 hours,48 hours after imaging.Two methods were used to diagnose CIN.A:detecting the level of Scr;B:detecting the level of serum Cys-C.The specificity and sensitivity of the above two methods were analyzed respectively.Results:Compared with that before imaging[(1.03±0.18)mg/L],the serum Cys-C increased significantly at 24 hours[(1.27±0.21)mg/L] and 48 hours[(1.31±0.26)mg/L] after imaging(F=39.542,P=0.031).By method A,the incidence of CIN were 6.57% at 24 hours after imaging and 7.20% at 48 hours after imaging,which were lower than those by method B(10.17% and 10.81%,χ2=262.359 and 236.669,P<0.001).By method B,the specificity and sensitivity of diagnosing CIN were 96.77% and 95.92% at 24 hours after imaging,91.18% and 95.43% at 48 hours after imaging.Conclusion:The level of serum Cys-C could be a sensitive marker to diagnose CIN in early stage.

  • 【文献出处】 郑州大学学报(医学版) ,Journal of Zhengzhou University(Medical Sciences) , 编辑部邮箱 ,2012年06期
  • 【分类号】R816.2;R692.9
  • 【被引频次】12
  • 【下载频次】339
节点文献中: 

本文链接的文献网络图示:

本文的引文网络