节点文献
二维数字图像相关方法的拉伸实验误差分析
An investigation of the experimental error of 2-D DIC method applied to tensile strain measurement
【摘要】 对数字图像相关(DIC)方法的拉伸实验误差进行了系统分析。通过刚体运动实验,从软件模拟计算和硬件两方面研究了DIC方法的实验误差,同时,根据成像原理,分析了离面位移对实验结果的影响。为了检验测试系统的测量精度,将DIC方法与多晶铜试样拉伸实验相结合,比较了不同实验条件下DIC方法与应变片测量的结果,分析认为测量误差主要来源于摄像机噪声及离面位移。鉴于这两种误差难以消除,探索了一种误差修正方法,对系统误差进行修正并得到满意结果。
【Abstract】 The errors of digital image correlation(DIC) method were systematically analyzed.Based on rigid-body motion,both the numerical and experimental errors related to DIC were investigated,and the influence of out-of-plane displacement was analyzed theoretically.In order to verify the accuracy of the home-developed DIC technique,the DIC method was compared with the strain gauge by measuring the same strain on a large copper specimen under tension.The result of the analysis indicates that the errors were originated from the noise of digital camera and the out-of-plane displacement of the whole measurement system.The system error was then calibrated and a better result was obtained.
【Key words】 digital image correlation(DIC); error analysis; rigid-body motion; out-of-plane displacement;
- 【文献出处】 光学仪器 ,Optical Instruments , 编辑部邮箱 ,2012年03期
- 【分类号】TP391.41
- 【被引频次】15
- 【下载频次】478