节点文献

微电解/Fenton法深度处理土霉素废水的研究

Advanced Treatment of Oxytetracycline Wastewater Using Microelectrolysis and Fenton Method

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 李再兴剧盼盼左剑恶赵庆军梁静芳余忻

【Author】 LI Zai-xing1,2,JU Pan-pan2,ZUO Jian-e1,ZHAO Qing-jun3,LIANG Jing-fang2, YU Xin1(1.School of Environment,Tsinghua University,Beijing 100084,China;2.School of Environmental Science and Engineering,Hebei University of Science and Technology, Shijiazhuang 050018,China;3.Shijiazhuang Qiaoxi WWTP,Shijiazhuang 050018,China)

【机构】 清华大学环境学院河北科技大学环境科学与工程学院石家庄市桥西污水处理厂

【摘要】 采用微电解/Fenton法对土霉素废水二级出水进行深度处理。正交和单因素试验结果表明,微电解法的最佳工艺条件:Fe投量为125 g/L、铁炭质量比为1.5∶1、初始pH值为4.0、反应时间为2 h,在进水COD为361~395 mg/L的条件下,处理后出水COD可降至198~207 mg/L,对COD的去除率可达44%以上;采用Fenton法进一步处理微电解出水,其最佳工艺条件:H2O2(浓度为30%)投加量为2 mL/L、初始pH值为3.0、反应时间为60 min,处理后出水COD<120 mg/L,组合工艺对COD的总去除率达到70%以上,满足《发酵类制药工业水污染物排放标准》(GB21903—2008)的要求。

【Abstract】 Advanced treatment experiments for secondary effluent of oxytetracycline wastewater were studied by micro-electrolysis and Fenton method.The results of orthogonal experiments and single factor experiments showed that the optimum conditions of micro-electrolysis method were as follows: the dosage of Fe was 125 g/L,the mass ratio of Fe to C was 1.5 ∶ 1,the initial pH was 4.0,and the reaction time was 2 h.The concentration of COD was reduced from 361-395 mg/L to 198-207 mg/L,and the removal rate was above 44%.The optimum conditions of Fenton method for treating the micro-electrolysis effluent were as follows: the dosage of 30% H2O2 was 2 mL/L,the initial pH was 3.0,and the reaction time was 60 min.The concentration of COD in the final effluent was less than 120 mg/L,and the total removal rate was more than 70%.The final effluent met the Discharge Standards of Water Pollutants for Pharmaceutical Industry—Fermentation Products Category(GB 21903-2008).

【基金】 国家水体污染控制与治理科技重大专项(2008ZX07529-006)
  • 【文献出处】 中国给水排水 ,China Water & Wastewater , 编辑部邮箱 ,2012年05期
  • 【分类号】X787
  • 【被引频次】27
  • 【下载频次】379
节点文献中: 

本文链接的文献网络图示:

本文的引文网络