S0910型轴承振动测量仪台差原因分析
Cause Analysis on Difference in Measured Values of Bearing Vibration Measuring Instrument S0910
【摘要】 针对日常检测用S0910型轴承振动测量仪之间的台差,从其传感系统、机械驱动装置及测量电箱等方面进行试验分析,结果表明,造成测振仪之间测值差异的主要原因是机械驱动系统的基础振动。
【Abstract】 According to the difference in measured values of bearing vibration measuring instrument S0910 in daily test,the test,verification,analysis and comparison are carried out from the aspects of sensed system,mechanical driving device and gauging electric box.The results show that the main reason for the difference in measured values of vibration measuring instrument is the foundation vibration of the mechanical driving system.
- 【文献出处】 轴承 ,Bearing , 编辑部邮箱 ,2012年03期
- 【分类号】TH825
- 【被引频次】2
- 【下载频次】94