S0910型轴承振动测量仪台差原因分析

Cause Analysis on Difference in Measured Values of Bearing Vibration Measuring Instrument S0910

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈彦付丽霞王家亮赵俊宏

【Author】 CHEN Yan1,FU Li-xia1,WANG Jia-liang2,ZHAO Jun-hong3(1.Shanghai Tianan Bearing Co.,Ltd.,Shanghai 201108,China;2.Shanghai Bearing Technology Research Institute, Shanghai 200031,China;3.Luoyang Bearing Science and Technology Co.,Ltd.,Luoyang 471039,China)

【机构】 上海天安轴承有限公司上海市轴承技术研究所洛阳轴研科技股份有限公司

【摘要】 针对日常检测用S0910型轴承振动测量仪之间的台差,从其传感系统、机械驱动装置及测量电箱等方面进行试验分析,结果表明,造成测振仪之间测值差异的主要原因是机械驱动系统的基础振动。

【Abstract】 According to the difference in measured values of bearing vibration measuring instrument S0910 in daily test,the test,verification,analysis and comparison are carried out from the aspects of sensed system,mechanical driving device and gauging electric box.The results show that the main reason for the difference in measured values of vibration measuring instrument is the foundation vibration of the mechanical driving system.