ICP-AES法测定聚氯化铝中氧化铝

The determination of Al2O3 in poly aluminium chloride by ICP-AES

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 许风华孙芳徐云斌胡迅

【Author】 XU Feng-hua,SUN Fang,XU Yun-bin,HU Xun(Wuhan Centers for Disease Control and Prevention,Wuhan 430015,China)

【机构】 武汉市疾病预防控制中心

【摘要】 目的:建立ICP-AES法测定聚氯化铝中氧化铝含量的方法。方法:样品经消解后应用ICP-AES法测定聚氯化铝中氧化铝。结果:此法回收率在99%~102%;精密度在0.44%~0.52%;与国标方法比对,结果满意。结论:本法操作简便、干扰少、准确度高、线性范围宽,适用于聚氯化铝中氧化铝含量的测定。

【Abstract】 Objective:To establish a method for determination of Al2O3 in poly aluminium chloride by ICP-AES.Methods: The content of Al2O3 was determined by ICP-AES after the samples were digested.Results:The recovery was in the range of 99%~102%.The precision was in the range of 0.44%~0.52%.Conclusion:The method is simple and accurate with little interference and a wide linear range.It is feasible for determination of Al2O3 in poly aluminium chloride.