Multi-element Ultrasound Phased Array Applicator for the Ablation of Deep-seated Tissue

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 吉翔沈国峰白景峰李德辉余瑛乔杉陈亚珠

【Author】 JI Xiang,SHEN Guo-feng,BAI Jing-feng,LI De-hui,YU Ying,QIAO Shan,CHEN Ya-zhu(Biomedical Instrument Institute,Med-X Research Institute,Shanghai Jiaotong University,Shanghai 200030,China)

【机构】 Biomedical Instrument Institute,Med-X Research Institute,Shanghai Jiaotong University

【摘要】 High-intensity focused ultrasound (HIFU) has attracted increasing interests as a promising noninvasive modality for the treatment of deep tumors in the thoracic and abdominal cavity.A 90-element HIFU spherical phased array applicator operated at 1 MHz has been developed for deep tissue ablation.The spherical array with a 5 cm wide central hole has a 21 cm diameter and an 18 cm radius of curvature.Annular element distribution with unequal element spacing is used to reduce the number of elements.The array is constructed with piezoelectric lead zirconate titanate (PZT-8) circular elements that are 1.4 cm in diameter and have a wall with thickness of 0.2 cm.The array offers an effective ablating depth of at least 8 cm in the tissue for both simulations and ex vivo experiments.The simulations demonstrate that the developed array can steer the focus with good quality of intensity distributions up to 6 mm off center over ranges from 17 to 21 cm when the water depth is set at 11 cm.We also present the beam focusing capability in deep tissue through a series of ex vivo experiments by measuring discoloration areas after sonications.These results indicate that the developed array is ideal for the ablation of deep-seated tissue.

【Abstract】 High-intensity focused ultrasound (HIFU) has attracted increasing interests as a promising noninvasive modality for the treatment of deep tumors in the thoracic and abdominal cavity.A 90-element HIFU spherical phased array applicator operated at 1 MHz has been developed for deep tissue ablation.The spherical array with a 5 cm wide central hole has a 21 cm diameter and an 18 cm radius of curvature.Annular element distribution with unequal element spacing is used to reduce the number of elements.The array is constructed with piezoelectric lead zirconate titanate (PZT-8) circular elements that are 1.4 cm in diameter and have a wall with thickness of 0.2 cm.The array offers an effective ablating depth of at least 8 cm in the tissue for both simulations and ex vivo experiments.The simulations demonstrate that the developed array can steer the focus with good quality of intensity distributions up to 6 mm off center over ranges from 17 to 21 cm when the water depth is set at 11 cm.We also present the beam focusing capability in deep tissue through a series of ex vivo experiments by measuring discoloration areas after sonications.These results indicate that the developed array is ideal for the ablation of deep-seated tissue.

【基金】 the National Natural Science Foundation of China(No. 30800246);the Shanghai Key Technologies R&D Program of China(No. 09441500900);the Med-X Shanghai Engineering Center Foundation(No. 08DZ2211201)
  • 【文献出处】 Journal of Shanghai Jiaotong University(Science) ,上海交通大学学报(英文版) , 编辑部邮箱 ,2011年01期
  • 【分类号】R730.5
  • 【被引频次】11
  • 【下载频次】98
节点文献中: 

本文链接的文献网络图示:

本文的引文网络