【摘要】 生活给水系统设计时,将室内外给水管网分成两套,结合实际情况从安全、经济以及维护管理等因素考虑,在地下室布置成立体双环状给水系统;生活热水采用一台容积式浮动盘管热交换器换热供给热水;从理论上论证了组合型消防栓箱在本工程中的适用性和优越性,提出可将灭火器和消火栓位置设于一处的观点供大家在设计上参考。

【Abstract】 The domestic water supply systems indoor and outdoor were designed separately.Consideration of the factors such as safety,economy and maintenance,they were laid out as stereo double circular water system in the basement.A volumetric floating coil heat exchanger was adopted for domestic hot water.The applicability and superiority of hydrant boxes combination was theoretically proved.It proposed that setting the fire extinguisher and fire hydrant at a same place,which was helpful for future design as a reference.