【摘要】 对某电厂机组补给水的机械加速澄清池进行出力调整试验,重新筛选了混凝剂和助凝剂,混凝剂选用PAC 1,投加量为30mg/L,助凝剂PAM的投加量为0.6mg/L。经过调整后,2个机械加速澄清池的总出力从300m3/h提高至670m3/h,满足机组供水的要求。
【Abstract】 The output capacity of mechanically accelerated clarifiers of make-up water for one thermal power unit has been regulated,reselecting the coagulant and coagulant aid,selecting PACI as the coagulant,injecting rate being 30 mg/L;and selecting PAM as coagulant aid,injecting rate being 0.6 mg/L.Through regulation,the total output capacity of two mechanically accelerated clarifiers has been enhanced from 300 m3/h to 670 m3/h,reaching the requirements of water supply for the unit.