节点文献
杆箍缩二极管X射线焦斑的成像法测量
Imaging measurement of X-ray spot of rod-pinch diode radiographic source
【摘要】 X射线源的焦斑尺寸是反映杆箍缩二极管射线源成像性能的重要参数。利用针孔成像法对MeV级脉冲X射线源的焦斑进行了2维图像测量。厚针孔采用直孔段加单锥体结构,直孔段孔径为0.2 mm。对于0.5 MeV的X射线,5倍成像倍率下调制传递函数值为0.5时空间分辨达到2.0 lp.mm-1。图像采集系统由闪烁体、物镜和CCD相机组成,物镜的成像倍率约0.34。实验结果经过模糊校正后,得到了焦斑的图像和调制传递函数。根据调制传递函数值为0.5时对应的空间频率值,给出X射线源焦斑的尺寸。阳极杆直径为1.2 mm时,X射线源焦斑的高斯分布等效直径为0.86 mm。
【Abstract】 A pulsed X-ray radiographic source based on inductive voltage adder(IVA) and rod-pinch diode(RPD) is developed at the Northwest Institute of Nuclear Technology.The X-ray spot size of RPD is a critical parameter to evaluate the spatial resolution performance for radiography.Using thick pinhole imaging technique,two-dimension images of the RPD X-ray spots have been measured.A pinhole with 0.2-mm-diameter was designed and an image acquirement system based on a lutetium-oxyorthosilicate-crystal scintillator,a lens and a CCD camera was established.The magnifications of the pinhole and the lens are about 5 and 0.34,respectively.The spatial resolution of the pinhole imaging layout is 2.0 lp·mm-1 at the modulation transfer function(MTF) of 0.5 for 0.5 MeV X-ray.Through the restoration of the blurred spot image,the X-ray spot images were obtained.The spot sizes,determined by the spatial frequency at 0.5 MTF,decrease from 0.86 mm for 1.2-mm-diameter rod to 0.745 mm for 0.8-mm-diameter rod.
【Key words】 rod-pinch diode; pulsed X-ray source; spot size; pinhole; imaging measurement;
- 【文献出处】 强激光与粒子束 ,High Power Laser and Particle Beams , 编辑部邮箱 ,2011年02期
- 【分类号】TL503
- 【被引频次】9
- 【下载频次】79