【摘要】 结合某居住小区二级管网,对该小区各热力入口的水力平衡度进行了测量计算,水力失调现象比较严重,分析了水力失调原因,提出改善方案。
【Abstract】 Combined with the secondary circuit in a residential area,the degrees of hydraulic balance at various consumer heat inlets of the residential area are measured and calculated,and the hydraulic misadjustment is severe.The reasons for hydraulic misadjustment are analyzed,and the solution scheme is proposed.
【关键词】 热力站;
二级管网;
热力入口;
水力失调;
水力平衡度;
【Key words】 substation; secondary circuit; consumer heat inlet; hydraulic misadjustment; degree of hydraulic balance;