节点文献

电感耦合等离子体原子发射光谱法测定自来水中铜、汞和铅

ICP-AES Determination of Copper Mercury and Lead in Tap Water

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈金忠陈凤玲丁振瑞梁伟华李旭

【Author】 CHEN Jin-zhong,CHEN Feng-ling,DING Zhen-rui,LIANG Wei-hua,LI Xu (College of Physics and Technology,Hebei University,Baoding 071002,China)

【机构】 河北大学物理科学与技术学院

【摘要】 采用电感耦合等离子体原子发射光谱法测定自来水中痕量铜、汞和铅。自来水样加入硝酸(2+98)溶液调节溶液酸度,加入有机添加剂正丙醇提高被测元素的谱线强度及增大光谱的信背比。分析中采用高频发生器功率1100W和载气压力230kPa。在优化的试验条件下,铜、汞和铅的方法检出限(3s)依次为2.32,8.34,5.16μg·L-1。应用此法平行测定自来水样5次,铜、汞和铅的相对标准偏差(n=5)依次为3.3%,8.0%,9.3%。

【Abstract】 ICP-AES was applied to the determination of trace amout of Cu,Hg and Pb in tap water,The acidity of water sample was adjusied with HNO3(2+98)solution,and n-propyl alcohol was added to enhance intensity of spectral lines of the 3 elements determined and to raise the signal to background ratio of the spectra. High-frequency power of 1100 W and atomizing pressure of 230 kPa were taken in the analysis.Under the optimized conditions,detection limits(3s)of the method found were 2.32μg·L-1for Cu,8.34μg·L-1for Hg and 5.16μg·L-1for Pb.The proposed method was used in the analysis of samples of tap water,and values of RSD’s(n=5)of Cu.Hg and Pb found were 3.3%.8.0%and 9.3%respectively.

【关键词】 电感耦合等离子体原子发射光谱法正丙醇自来水
【Key words】 ICP-AESn-Propyl alcoholTap waterCopperMercuryLead
【基金】 河北省自然科学基金资助项目(A2008000560)
  • 【文献出处】 理化检验(化学分册) ,Physical Testing and Chemical Analysis(Part B:Chemical Analysis) , 编辑部邮箱 ,2011年04期
  • 【分类号】TU991.21
  • 【被引频次】28
  • 【下载频次】679
节点文献中: 

本文链接的文献网络图示:

本文的引文网络