Novel correction method for X-ray beam energy fluctuation of high energy DR system with a linear detector

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 杨民陈浩孟凡勇魏东波

【Author】 YANG Min 1;1) CHEN Hao 2 MENG Fan-Yong 3 WEI Dong-Bo1 1 School of Mechanical Engineering and Automation, Beijing Univ. of Aeronautics and Astronautics, Beijing 100191, China 2 Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900, China 3 State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China

【机构】 School of Mechanical Engineering and Automation,Beijing Univ.of Aeronautics and AstronauticsInstitute of Applied Electronics,China Academy of Engineering PhysicsState Key Laboratory of Multiphase Complex Systems,Institute of Process Engineering,Chinese Academy of Sciences

【摘要】 A high energy digital radiography (DR) testing system has generated diverse scientific and technological interest in the field of industrial non-destructive testing. However, due to the limitations of manufac-turing technology for accelerators, an energy fluctuation of the X-ray beam exists and leads to bright and dark streak artifacts in the DR image. Here we report the utilization of a new software-based method to correct the fluctuation artifacts. The correction method is performed using a high pass filtering operation to extract the high frequency information that reflects the X-ray beam energy fluctuation, and then subtracting it from the original image. Our experimental results show that this method is able to rule out the artifacts effectively and is readily implemented on a practical scanning system.

【Abstract】 A high energy digital radiography (DR) testing system has generated diverse scientific and technological interest in the field of industrial non-destructive testing. However, due to the limitations of manufac-turing technology for accelerators, an energy fluctuation of the X-ray beam exists and leads to bright and dark streak artifacts in the DR image. Here we report the utilization of a new software-based method to correct the fluctuation artifacts. The correction method is performed using a high pass filtering operation to extract the high frequency information that reflects the X-ray beam energy fluctuation, and then subtracting it from the original image. Our experimental results show that this method is able to rule out the artifacts effectively and is readily implemented on a practical scanning system.

【基金】 Supported by National Natural Science Foundation of China (60872080, 61077011);National State Key Laboratory of Multiphase Complex Systems (MPCS-2011-D-03);Beijing Municipal Commission of Education (BMCE) under the Joint-Building Project
  • 【文献出处】 中国物理C ,Chinese Physics C , 编辑部邮箱 ,2011年11期
  • 【分类号】O434.19
  • 【被引频次】2
  • 【下载频次】36