节点文献

γ全谱法测定空气吸收剂量率的M-C法应用

Application of Monte Carlo method in determination of air absorbed dose rate from a full γ-ray spectrum

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张江云黄宁唐丽丽刘艳芳张光华

【Author】 ZHANG Jiangyun1 HUANG Ning1 TANG Lili 2 LIU Yanfang2 ZHANG Guanghua3 1(Key Laboratory for Radiation Physics and Technology of Ministry of Education,Institute of Nuclear Science and Technology,Sichuan University;Chengdu 610064,China) 2(College of Nuclear Technology and Automation Engineering,Chengdu University of Technology,Chengdu 610059,China) 3(School of Physics,Sichuan University Applied Physics Electronics Laboratory,Chengdu 610064,China)

【机构】 四川大学原子核科学技术研究所辐射物理及技术教育部重点实验室成都理工大学核技术与自动化工程学院四川大学物理学院应用电子物理实验室

【摘要】 γ辐射场剂量的测量可以通过γ剂量率仪或谱-剂量转换的方法来实现。其中一种谱-剂量转换方法为γ全谱法(G(E)函数),即通过建立能谱转换函数G(E),把测得的能谱直接换算成剂量,G(E)函数的系数可通过标准源刻度获得,但标准源及其能量分布会受实际条件限制。我们采用蒙特卡罗方法,在0.1–2.5 MeV能量范围内较均匀地选择了11个能量点,用MCNP5软件模拟了不同尺寸NaI(Tl)晶体的响应能谱,并把它们作为标准谱求解得到了G(E)函数;最后利用该G(E)函数计算各模拟能谱的剂量,并与理论计算值进行比较,平均误差<4%。

【Abstract】 The dosimetric properties of a gamma-radiation field can be measured by a dose-rate meter or by a gamma-spectrometer with spectrum-dose conversion.One of the spectrum dose conversion methods is to evaluate the radiation dosedirectly from integrating the observed pulse height spectrum weighted by a G(E) function,instead of making spectrum analysis.In this paper,energy spectra of 11 single energy point sources in 0.1–2.5 MeV are simulated by using Monte Carlo software MCNP5 for NaI(Tl) detectors of Φ 75 mm×75 mm,Φ 50 mm×50 mm and Φ 25 mm×25 mm.The energy spectra are used as standard spectrum to calculate the G(E) value,so as to calculate corresponding doses.Comparing the results with theoretical value,the error is less than 1.5%.Finally,the G(E)-based γ dose rate of radiation field agreed well(within 5%) with the dose rate measured by a dosimeter.

【关键词】 γ全谱法MCNP5G(E)函数
【Key words】 γ full spectrum methodMCNP5G(E) function
  • 【分类号】TL817.2
  • 【被引频次】8
  • 【下载频次】243
节点文献中: 

本文链接的文献网络图示:

本文的引文网络