节点文献
集美污水处理厂生物滤池除臭工程设计
Engineering Application of Biofilter Deodorization in Jimei Sewage Treatment Plant
【摘要】 集美污水处理厂预处理区除臭工程采用生物滤池法除臭,根据除臭气量及臭气浓度,设计1.4 m的滤池填料高度及250 m3/(m2.h)的表面负荷,合理配置附属设备,运行效果良好,可满足《城镇污水处理厂污染物排放标准》(GB 18918—2002)中的臭气排放要求。
【Abstract】 The deodorization biofilter is used in pretreatment deodorization project of Jimei Sewage Treatment Plant.According to odor volume and concentration,the media height of 1.4 m and surface loading of 250 m3/(m2·h) are designed with the rational allocation of ancillary equipment.The biofilter has good operating results,and meets the requirements for odor control in Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant(GB 18918-2002).
- 【文献出处】 中国给水排水 ,China Water & Wastewater , 编辑部邮箱 ,2011年18期
- 【分类号】X703
- 【被引频次】5
- 【下载频次】670