节点文献
吹扫捕集-GC-MS测定水中痕量氯乙酸的研究
Study on Determination of Trace Chloroacetic Acids in Water Using Purge and Trap-GC-MS
【摘要】 固相萃取-吹扫捕集-气质联用法对一氯乙酸、二氯乙酸、三氯乙酸进行分析,水样体积为200 mL时,此方法检出限分别为:0.004 mg/L、0.0008 mg/L、0.002 mg/L,加标回收率为94%~107%,5次平行测定的相对标准偏差为3.78%~5.96%。取1000 mL广州市自来水测定其中氯乙酸含量的结果是:一氯乙酸5.37μg/L、二氯乙酸10.84μg/L、三氯乙酸8.74μg/L。
【Abstract】 The analytical performance of techniques based on the combination of solid phase extraction and purge and trap with gas chromatography-mass spectrometry were studied.It was found that the detection limits for monochloroacetie acid,diehloroaeetic acid and trichloroacetic acid by purge and trap were 0.004 mg/L,0.0008 mg/L and 0.002 mg/L,respectively.The recovery was in the range of 94 %~107 % with RSD(n=5) of 3.78 %~5.96 %.By the proposed method,the contents of monochloroacetie acid,diehloroaeetic acid and trichloroacetic acid in tap water samples collected from Guangzhou were found to be 5.37μg/L,10.84 μg /L and 8.74 μg /L,respectively.
【Key words】 chloroacetie acid; gas chromatography-mass spectrometry; solid phase extraction; purge and trap; water;
- 【文献出处】 广东化工 ,Guangdong Chemical Industry , 编辑部邮箱 ,2011年02期
- 【分类号】X832
- 【被引频次】3