台山电厂烟气换热器结垢堵塞的运行分析
Operational Analysis on Scaling and Blocking in GGH of Taishan Power Plant
【摘要】 对造成烟气换热器(gas gas heater,GGH)结垢堵塞的根本原因——烟气携带石膏、除雾效果不佳、吹扫不足、煤种和石灰石品质下降等因素进行了具体分析,提出针对性的改进措施:对GGH设备进行改造,加装导流板;对机组进行运行调整。整改后,GGH结垢堵塞和差压升高的问题得到缓解。
【Abstract】 Fundamental reasons for scaling and blocking in gas-gas heater(GGH),such as gas with gypsum,poor defogging effect,insufficient purge,degradation of coal type and limestone quality and other factors are concretely analyzed,and targeted improvement approaches are proposed: redevelop the GGH equipment by installing deflector and carry on operation adjustment.After the improvement,problems concerning scaling and blocking in GGH and rise of differential pressure get relieved.
【关键词】 烟气换热器;
增压风机;
结垢;
堵塞;
吹扫方式;
【Key words】 gas-gas heater; booster fan; scaling; blocking; purge mode;
【Key words】 gas-gas heater; booster fan; scaling; blocking; purge mode;
- 【文献出处】 广东电力 ,Guangdong Electric Power , 编辑部邮箱 ,2011年01期
- 【分类号】X701.3
- 【被引频次】1
- 【下载频次】106