电站高压加热器爆破泄漏原因探讨

Analysis and Counter Measures of High Pressure Heater Crack and Leakage in Power Plant

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王兴义冀晋川李文亮

【Author】 WANG Xing-yi,JI Jin-chuan,LI Wen-liang(Shanxi Electric Power Research Institute,Taiyuan,Shanxi 030001,China)

【机构】 山西电力科学研究院

【摘要】 以几起电站高压加热器爆破、泄漏事故为例,从高压加热器的设计、制造、运行、维护、检验等方面对高压加热器事故原因进行分析,提出了相应的设计改进措施、制造运行注意事项以及事故发生后的处理方法,从而减少高压加热器事故的发生,保证高压加热器安全运行,提高投入率。

【Abstract】 Taking several accidents on high-pressure heater(HP heater) crack and leakage in power plant as examples,the accident causes in terms of design,manufacture,operation,maintenance and inspection are analyzed.In order to reduce the accident on HP heater and achieve safety and enhance the input ratio of HP heater,corresponding improvement measures on design and the item which should be paid attention to in course of manufacture and operation are proposed,and accident disposal methods are put forward.

【关键词】 高压加热器爆破泄漏
【Key words】 high-pressure heatercrackleakage