节点文献
汽轮机驱动引风机设计方案优化
The Optimized Design Scheme for Turbine-driven Induced Draft Fan
【摘要】 为了减少厂用电,提高机组效率,提出了引风机采用汽轮机驱动的方案,并对采用背压式汽轮机和凝汽式汽轮机2种系统设计进行了分析。同时结合华能沁北发电厂三期工程,将2种汽轮机方案与电动驱动方案进行了技术经济比较,得出了相关比较结论,给相关的工程设计提供参考。
【Abstract】 In order to reduce auxiliary power consumption and improve the unit efficiency, a scheme is proposed that the steam turbine is used to drive the induced draft fan (IDF). An analysis is conducted on the design of two systems in which back pressure stream turbine and condensing turbine are adopted respectively. Based on the phase-3 Huaneng Qinbei Power Plant, two steam-driven and motor-driven schemes are compared in terms of technology and economy and some conclusions are achieved, which can provide a reference for relevant engineering design.
【关键词】 引风机;
汽轮机驱动;
凝汽式汽轮机;
背压式汽轮机;
电动机驱动;
技术经济;
【Key words】 induced draft fan; steam turbine-driven; condensing turbine; back pressure turbine; motor-driven; technology and economy;
【Key words】 induced draft fan; steam turbine-driven; condensing turbine; back pressure turbine; motor-driven; technology and economy;
- 【文献出处】 电力建设 ,Electric Power Construction , 编辑部邮箱 ,2011年03期
- 【分类号】TM621
- 【被引频次】13
- 【下载频次】289