节点文献

注射用美罗培南中碳酸钠的原子吸收分光光度法检测

Determination of Sodium Carbonate in Meropenem for Injection by Atomic Absorption Spectrophotometry

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张冬苑华赫晓军付焱

【Author】 ZHANG Dong1,YUAN Hua1,HE Xiaojun1,FU Yan2*(1.Hebei Institute for Drug Control,Shijiazhuang 050011;2.Hebei Medical University,Shijiazhuang 050001)

【机构】 河北省药品检验所河北医科大学

【摘要】 建立了原子吸收分光光度法测定注射用美罗培南中的碳酸钠。以钠空心阴极灯为光源,采用空气-乙炔火焰原子化器,分析线330.3 nm。以氯化钠作对照品,结果氯化钠浓度为56~420μg/ml时线性关系良好,检测限为3.2μg/ml。碳酸钠的平均回收率为101.5%,RSD为2.6%。

【Abstract】 An atomic absorption spectrophotometry was established for the determination of sodium carbonate in meropenem for injection.An air and acetylene flame atomizer was used with hollow cathode lamp of sodium as the light source,and the test line at 330.3 nm.Sodium chloride was used as the reference substance.The calibration curve of sodium chloride was linear in the concentration range of 56-420 μg/ml.The limit of detection was 3.2 μg/ml.The recovery of sodium carbonate was 101.5%,with RSD of 2.6%.

【基金】 石家庄市科学技术研究与发展计划课题(09146923)
  • 【文献出处】 中国医药工业杂志 ,Chinese Journal of Pharmaceuticals , 编辑部邮箱 ,2010年11期
  • 【分类号】R927
  • 【被引频次】2
  • 【下载频次】125
节点文献中: 

本文链接的文献网络图示:

本文的引文网络