节点文献

蜂窝胞壁厌氧生物滤池处理焦化废水的中试研究

PILOT STUDY ON THE ANAEROBIC BIOLOGICAL FILTER WITH CELLULAR STRUCTURED FIBER FILLINGS FOR THE COKING WASTEWATER TREATMENT

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张光海毛异蔡建安

【Author】 Zhang Guanghai,Mao Yi,Cai Jianan (School of Architectural Engineering,Anhui University of Technology,Ma′anshan 243002,China)

【机构】 安徽工业大学建筑工程学院

【摘要】 采用新型蜂窝胞壁厌氧生物滤池用于A/A/O工艺处理焦化废水,研究了蜂窝胞壁厌氧生物滤池内COD的去除和氨化效果,以及pH、温度对氨化率的影响情况。结果表明,在进水COD平均为2370mg·L-1,NH3-N质量浓度为165mg·L-1的条件下,蜂窝胞壁厌氧生物滤池对COD的去除率平均为37%,氨化率平均为30%,与传统的厌氧生物滤池相比,具有水力负荷高、COD去除率高、pH和温度条件要求不高等特点。再经过后续缺氧和好氧工艺,出水COD和NH3-N均能够达到污水综合排放标准中的二级标准。

【Abstract】 The coking wastewater was treated with the anaerobic biological filter with cellular structured fiber fillings in A/A/O process. The removal of COD, the ammonification rate of NH3-N and the ammonification rate with the changes of pH and temperature were studied in the anaerobic reactor. The results showed that the average removal rate of COD and the ammonification rate were 37% and 30% when the influent COD was 2 370 mg·L-1 and NH3-N was 165 mg·L-1 during the anaerobic reactor. Comparing with the traditional anaerobic reactor, the anaerobic biological filter was characterized by its higher hydraulic load, higher removal rate of COD, and more medial condition of pH and temperature. The effluent concentration of COD and NH3-N achieved the secondary standard criteria specified in Integrated Standard of Wastewater Discharge during the A/A/O process.

  • 【文献出处】 水处理技术 ,Technology of Water Treatment , 编辑部邮箱 ,2010年02期
  • 【分类号】X784
  • 【被引频次】5