【作者】
谢宇广;
李卫东;
梁羽铁;
尤郑昀;
冒亚军;
张家文;
边渐鸣;
曹国富;
曹学香;
陈申见;
邓子艳;
傅成栋;
高原宁;
何康林;
何苗;
花春飞;
黄彬;
黄性涛;
季晓斌;
李飞;
李海波;
刘春秀;
刘怀民;
刘秋光;
刘锁;
刘英杰;
马秋梅;
马想;
毛泽普;
莫晓虎;
潘明华;
庞彩莹;
平荣刚;
秦亚红;
邱进发;
孙胜森;
孙永昭;
王纪科;
王亮亮;
文硕频;
伍灵慧;
徐敏;
严亮;
苑长征;
袁野;
张炳云;
张长春;
张建勇;
张学尧;
张瑶;
郑阳恒;
朱科军;
朱永生;
朱志丽;
邹佳恒;
【Author】
XIE Yu-Guang1,2;1) LI Wei-Dong1 LIANG Yu-Tie3 YOU Zheng-Yun3 MAO Ya-Jun3 ZHANG Jia-Wen1 BIAN Jian-Ming1,2 CAO Guo-Fu1,2 CAO Xue-Xiang1,2 CHEN Shen-Jian4 DENG Zi-Yan1 FU Cheng-Dong1,5 GAO Yuan-Ning5 HE Kang-Lin1 HE Miao1,2 HUA Chun-Fei6 HUANG Bin1,2 HUANG Xing-Tao7 JI Xiao-Bin1 LI Fei1 LI Hai-Bo1 LIU Chun-Xiu1 LIU Huai-Min1 LIU Qiu-Guang1,2 LIU Suo8 LIU Ying-Jie1 MA Qiu-Mei1 MA Xiang1,2 MAO Ze-Pu1 MO Xiao-Hu1 PAN Ming-Hua9 PANG Cai-Ying9 PING Rong-Gang1 QIN Ya-Hong6 QIU Jin-Fa1 SUN Sheng-Sen1 SUN Yong-Zhao1,2 WANG Ji-Ke1,2 WANG Liang-Liang1,2 WEN Shuo-Pin1 WU Ling-Hui1,2 XU Min10 YAN Liang1,2 YUAN Chang-Zheng1 YUAN Ye1 ZHANG Bing-Yun1 ZHANG Chang-Chun1 ZHANG Jian-Yong1 ZHANG Xue-Yao7 ZHANG Yao1 ZHENG Yang-Heng2 ZHU Ke-Jun1 ZHU Yong-Sheng1 ZHU Zhi-Li9 ZOU Jia-Heng7 1 Institute of High Energy Physics, CAS, Beijing 100049, China 2 Graduate University of Chinese Academy of Sciences, Beijing 100049, China 3 Peking University, Beijing 100871, China 4 Nanjing University, Nanjing 210093, China 5 Tsinghua University, Beijing 100084, China 6 Zhengzhou University, Zhengzhou 450001, China 7 Shandong University, Jinan 250100, China 8 Liaoning University, Shenyang 110036, China 9 Guangxi Normal University, Guilin 541004, China 10 Department of Modern Physics, University of Science and Technology of China, Hefei 230026, China
【机构】
Institute of High Energy Physics, CAS;
Graduate University of Chinese Academy of Sciences;
Peking University;
Nanjing University;
Tsinghua University;
Zhengzhou University;
Shandong University;
Liaoning University;
Guangxi Normal University;
Department of Modern Physics, University of Science and Technology of China;
【摘要】 The calibration algorithm for RPC-based muon detector at BESⅢ has been developed. The calibration method, calibration error and algorithm performance are studied. The primary results of efficiency and noise at layer, module and strip levels have been calibrated with cosmic ray data. The calibration constants are available for simulation and reconstruction tuning. The results of Monte Carlo and data are also compared to check the validation and reliability of the algorithm.更多还原
【Abstract】 The calibration algorithm for RPC-based muon detector at BESⅢ has been developed. The calibration method, calibration error and algorithm performance are studied. The primary results of efficiency and noise at layer, module and strip levels have been calibrated with cosmic ray data. The calibration constants are available for simulation and reconstruction tuning. The results of Monte Carlo and data are also compared to check the validation and reliability of the algorithm.更多还原
【基金】 Supported by CAS Knowledge Innovation Project(U-602, U-34);National Natural Science Foundation of China (10491300,10491303, 10605030, 10835001, 10821063);100 Talents Program of CAS (U-25 and U-54);National Basic Research Program of China (2009CB825208)