节点文献

Measurement of neutron cross sections and resonance parameters of 169Tm below 100 eV

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王文明李霞赵志祥周祖英于洪伟吴海成魏义祥T.F. WangG.N. KimM.W. LeeK.S. KimM.H. ChoI.S. KoW. Namkung

【Author】 WANG Wen-Ming1;1) LI Xia1 ZHAO Zhi-Xiang1 ZHOU Zu-Ying1 YU Hong-Wei1 WU Hai-Cheng1 WEI Yi-Xiang2 T.F.Wang3 G.N.Kim3 M.W.Lee3 K.S.Kim3 M.H.Cho4 I.S.Ko4 W.Namkung41 China Institute of Atomic Energy,Beijing 102413,China 2 Department of Engineering Physics,Tsinghua University,Beijing 100084,China 3 Department of Physics,Kyungpook National University,Daegu 702-701,Republic of Korea 4 Department of Physics,Pohang University of Science and Technology,Pohang 790-784,Republic of Korea

【机构】 China Institute of Atomic EnergyDepartment of Engineering Physics,Tsinghua UniversityDepartment of Physics,Kyungpook National UniversityDepartment of Physics,Pohang University of Science and Technology

【摘要】 The neutron total cross-sections of thulium(169Tm) were measured in the neutron energy region from 0.01 eV to 100 eV by using the time-of-flight method at the Pohang Neutron Facility,which consists of an electron linac,a water-cooled tantalum target with a water moderator,and a 12 m time of flight path.Two thulium plates with different thicknesses were used for the neutron transmission measurement.The background level was determined by using a notch-filter of Co,In,and Cd sheets.The present measurement was compared with the previous ones,and a new set of resonance parameters of 169Tm isotope was obtained from the transmission rate by using the SAMMY code,with a comparison with the recommended parameters by Mughabghab.

【Abstract】 The neutron total cross-sections of thulium(169Tm) were measured in the neutron energy region from 0.01 eV to 100 eV by using the time-of-flight method at the Pohang Neutron Facility,which consists of an electron linac,a water-cooled tantalum target with a water moderator,and a 12 m time of flight path.Two thulium plates with different thicknesses were used for the neutron transmission measurement.The background level was determined by using a notch-filter of Co,In,and Cd sheets.The present measurement was compared with the previous ones,and a new set of resonance parameters of 169Tm isotope was obtained from the transmission rate by using the SAMMY code,with a comparison with the recommended parameters by Mughabghab.

【关键词】 resonance parametersthuliumn-TOF methodSAMMY
【Key words】 resonance parametersthuliumn-TOF methodSAMMY
【基金】 the staff of the Pohang Accelerator Laboratory for the excellent operation of the electron linac and their strong support
  • 【文献出处】 中国物理C ,Chinese Physics C , 编辑部邮箱 ,2010年02期
  • 【分类号】O571.55
  • 【下载频次】21
节点文献中: 

本文链接的文献网络图示:

本文的引文网络