冷凝器流程布置对高温热泵性能影响的实验研究

Experimental Study on Effect of Refrigerant Circuitry in Condenser on Performance of High Temperature Heat Pump

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王方连之伟李智华周湘江

【Author】 WANG Fang~(1,2),LIAN Zhi-wei~(1,2),LI Zhi-hua~2,ZHOU Xiang-jiang~2(1.School of Energy and Environment Engineering,Zhongyuan University of Technology,Zhengzhou 450007,China;2.Institute of Refrigeration and Cryogenics,Shanghai Jiao Tong University,Shanghai 200240,China)

【机构】 中原工学院能源与环境学院上海交通大学制冷与低温工程研究所

【摘要】 本文进行了以HFC125为工质的高温热泵热力性能的实验研究,分析了有、无回热循环工况下,冷凝器不同流程布置形式对系统COP的影响。实验结果表明:无回热循环情况下,冷凝器串并联混合布置形式具有较好的效果,系统COP实测均值达3.0,且和理论值接近度达80%以上。本文研究结果为高温热泵系统的性能优化提供了依据。

【Abstract】 In this paper,experimental study on the performance of high temperature heat pump(HTHP) system using HFC125 as refrigerant was performed,and the influences of different refrigerant circuitries with and without regeneration cycle on COP were analyzed.The results indicated that the series-parallel arrangement of condenser without regeneration cycle was better than other conditions,the measured COP was up to 3.0,and over 80% proximity to the theoretical value.The findings of this paper would provide reference for performance optimization of HTHP system.

【关键词】 HFC125高温热泵冷凝器流程布置COP
【Key words】 HFC125high temperature heat pumpcondenserrefrigerant circuitryCOP
【基金】 国家自然科学基金资助项目(50676059)
  • 【分类号】TB65
  • 【被引频次】4