Fouling of organic fractionation on ultrafiltration membrane for drinking water treatment:a case study

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 康华何文杰刘秀红王东

【Author】 KANG Hua1,HE Wen-jie1,2,LIU Xiu-hong3,WANG Dong4(1.School of Municipal and Environmental Engineering,Harbin Institute of Technology,Harbin 150090,China;2.Tianjin WaterWorks Group Company Ltd,Tianjin 300040,China;3.Beijing Drainage Group Co.Ltd,Beijing 100044,China;4.Changchun Water Group Co.Ltd,Changchun 130021,China)

【机构】 School of Municipal and Environmental Engineering,Harbin Institute of TechnologyTianjin WaterWorks Group Company LtdBeijing Drainage Group Co.LtdChangchun Water Group Co.Ltd

【摘要】 The aim of this study was to obtain a better understanding of the range of organic molecular weight(MW)causing membrane fouling through the comparison between direct UF and in-line coagulation(without settling)/UF process.The experimental results indicated that,when raw water with organics was treated and the MW of more than half of the organics was less than 1 kDa,membrane fouling was rather serious by only UF and coagulation could improve the fouling for the treatment of raw water.Besides,coagulation/UF could remove organics in each region,and organics with MW greater than 30 kDa were the most possible matters causing membrane fouling,while organics with MW less than 1 kDa were impossibly responsible for membrane fouling due to few organics removed.Therefore,organics with MW greater than 30 kDa were the major factor of membrane fouling.

【Abstract】 The aim of this study was to obtain a better understanding of the range of organic molecular weight(MW)causing membrane fouling through the comparison between direct UF and in-line coagulation(without settling)/UF process.The experimental results indicated that,when raw water with organics was treated and the MW of more than half of the organics was less than 1 kDa,membrane fouling was rather serious by only UF and coagulation could improve the fouling for the treatment of raw water.Besides,coagulation/UF could remove organics in each region,and organics with MW greater than 30 kDa were the most possible matters causing membrane fouling,while organics with MW less than 1 kDa were impossibly responsible for membrane fouling due to few organics removed.Therefore,organics with MW greater than 30 kDa were the major factor of membrane fouling.

【基金】 Sponsored by the Tianjin Municipal Science and Technology Commission(Grant No.05FZZDSH00500)
  • 【文献出处】 Journal of Harbin Institute of Technology ,哈尔滨工业大学学报(英文版) , 编辑部邮箱 ,2010年06期
  • 【分类号】TU991.2
  • 【被引频次】1