节点文献

高效液相色谱法测定双氧水工作液中的蒽醌化合物

Determination of Anthraquinone in Hydrogen Peroxide Working-solution by High Performance Liquid Chromatography

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 洪江星

【Author】 Hong Jiang-xing (Analytical and TestingCenter,Fuzhou University,Fuzhou,Fujian350002,China)

【机构】 福州大学测试中心

【摘要】 本文探讨了采用液相色谱法检测双氧水工作液中蒽醌化合物的方法。流动相为甲醇:水=80:20,色谱柱为Zorbax XDB-C18(150×4.6mmid,5μm),流速为1.0mL·min-1。该方法的检出限分别为1.0mg·L-1和1.5mg·L-1,相对标准偏差范围为2.9%~4.7%,样品回收率为95.8%~103.5%。该法快速、灵敏度高、重现性好。

【Abstract】 In this paper,we developed a reversed-phase high performance liquid chromatography for the determination of anthraquinone in hydrogen peroxide working-solution. The mixtures were successfully isolated on a Zorbax C18 column (150× 4.6 mm id,5μm),using methanol-water (80:20,v/v) as the mobile phase at a flowrate of 1.0 mL.min-1. The limits of detection (LOD) were 1.0 mg.L-1 and 1.5 mg.L-1 respectively. Their recoveries were between 95.8%~103.5% and RSDs were 2.9%~4. 7%. It was a rapid,sensitive and reproducible method.

  • 【文献出处】 福建分析测试 ,Fujian Analysis & Testing , 编辑部邮箱 ,2010年03期
  • 【分类号】TQ123.6
  • 【被引频次】8
  • 【下载频次】207
节点文献中: 

本文链接的文献网络图示:

本文的引文网络