节点文献

Effect of sample diameter on primary dendrite spacing of directionally solidified Al-4%Cu alloy

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 屈敏刘林唐峰涛张军傅恒志

【Author】 QU Min, LIU Lin, TANG Feng-tao, ZHANG Jun, FU Heng-zhi State Key Laboratory of Solidification Processing, North western Polytechnical University, Xi’an 710072, China

【机构】 State Key Laboratory of Solidification Processing, Northwestern Polytechnical University

【摘要】 The relationship between primary dendrite arm spacing and sample diameter was studied during directional solidification for Al-4%Cu (mass fraction) alloy. It is shown that primary dendrite spacing is decreased with the decrease of the sample diameter at given growth rate. By regressing the relationship between primary dendrite arm spacing and the growth rate, the primary dendrite arm spacing complies with 461.76v-0.53, 417.92v-0.28 and 415.83v-0.25 for the sample diameter of 1.8, 3.5 and 7.2 mm, respectively. The primary dendrite spacing, growth rate and thermal gradient for different sample diameters comply with 28.77v-0.35G-0.70, 23.17v-0.35G-0.70 and 23.84v-0.35G-0.70, respectively. They are all consistent with the theoretical model λ1 =k b v-a1G-b1, and b1/a1=2. By analyzing the experimental results with classical models, it is shown that KURZ-FISHER model fits for the primary dendrite spacing in smaller sample diameters with weaker thermosolute convection. Whereas TRIVEDI model is suitable for describing primary dendrite arm spacing with a larger diameter (d>2 mm) where convection should be considered.

【Abstract】 The relationship between primary dendrite arm spacing and sample diameter was studied during directional solidification for Al-4%Cu (mass fraction) alloy. It is shown that primary dendrite spacing is decreased with the decrease of the sample diameter at given growth rate. By regressing the relationship between primary dendrite arm spacing and the growth rate, the primary dendrite arm spacing complies with 461.76v-0.53, 417.92v-0.28 and 415.83v-0.25 for the sample diameter of 1.8, 3.5 and 7.2 mm, respectively. The primary dendrite spacing, growth rate and thermal gradient for different sample diameters comply with 28.77v-0.35G-0.70, 23.17v-0.35G-0.70 and 23.84v-0.35G-0.70, respectively. They are all consistent with the theoretical model λ1 =k b v-a1G-b1, and b1/a1=2. By analyzing the experimental results with classical models, it is shown that KURZ-FISHER model fits for the primary dendrite spacing in smaller sample diameters with weaker thermosolute convection. Whereas TRIVEDI model is suitable for describing primary dendrite arm spacing with a larger diameter (d>2 mm) where convection should be considered.

【基金】 Project(50771081) supported by the National Natural Science Foundation of China
  • 【文献出处】 Transactions of Nonferrous Metals Society of China ,中国有色金属学会会刊(英文版) , 编辑部邮箱 ,2009年01期
  • 【分类号】TG146.21
  • 【被引频次】7
  • 【下载频次】57
节点文献中: 

本文链接的文献网络图示:

本文的引文网络